NOVEMBER, 2000NEC America, Inc.NDA-24318ISSUE 1STOCK # 200818IPTRK Circuit Card System Manual®
NDA-24318 CHAPTER 1Page 3Issue 1INTRODUCTIONFigure 1-3 represents a block diagram example of CCIS Networking via IP [C-163]. For more detailedinformat
CHAPTER 1 NDA-24318Page 4Issue 1INTRODUCTIONFigure 1-4 represents a block diagram example of CCIS Networking via IP [C-163] when an IPTRK circuit card
NDA-24318 CHAPTER 1Page 5Issue 1INTRODUCTIONFigure 1-5 represents a block diagram example of FCCS Networking via IP [F-36]. For more detailedinformati
CHAPTER 1 NDA-24318Page 6Issue 1INTRODUCTION3. HOW TO FOLLOW THIS MANUAL AND RELATED REFERENCE MANUALSThis manual describes only items related to the
NDA-24318 CHAPTER 2Page 7Issue 1CIRCUIT CARD EXPLANATIONSCHAPTER 2 CIRCUIT CARD EXPLANATIONS1. GENERALThis chapter provides detailed explanations for
CHAPTER 2 NDA-24318Page 8Issue 1CIRCUIT CARD EXPLANATIONS2.2 Mounting Location/ConditionMounting location/condition of this card is shown below. Mount
NDA-24318 CHAPTER 2Page 9Issue 1CIRCUIT CARD EXPLANATIONSFigure 2-3 Port Assignment for PA-8IPTB Circuit CardPWRPWREx. Slot 05 Ex. Slot 21
CHAPTER 2 NDA-24318Page 10Issue 1CIRCUIT CARD EXPLANATIONS2.3 Face Layout of Lamps, Switches and ConnectorsThe face layout of lamps, switches and conn
NDA-24318 CHAPTER 2Page 11Issue 1CIRCUIT CARD EXPLANATIONS2.5 Switch SettingsThe meaning of each switch on this card is shown below:IP-LINK Green Ligh
CHAPTER 2 NDA-24318Page 12Issue 1CIRCUIT CARD EXPLANATIONSSW101ON External Ether 100 Mbps: Fixed Note 1OFF × External Ether 10 Mbps: Fixed Note 12ON I
LIABILITY DISCLAIMERNEC America, Inc. reserves the right to change the specifications, functions, orfeatures, at any time, without notice.NEC America,
NDA-24318 CHAPTER 2Page 13Issue 1CIRCUIT CARD EXPLANATIONSSW201~6Designation of Flexible PAD Value Note 17ONFixed to OFF.OFF×8ONFixed to OFF.OFF×Table
CHAPTER 2 NDA-24318Page 14Issue 1CIRCUIT CARD EXPLANATIONSNote 1: Flexible PAD is made effective when SW10-7 = ON, and PAD No. = 4 in Table 2-3.Note 2
NDA-24318 CHAPTER 2Page 15Issue 1CIRCUIT CARD EXPLANATIONSNote: Flexible PAD is used when SW10-7 is set ON. For details on Flexible PAD values, refer
CHAPTER 2 NDA-24318Page 16Issue 1CIRCUIT CARD EXPLANATIONSWhen using an IPTRK circuit card for FCCS Networking via IP [F-36] (Point-to-Multipoint Conn
NDA-24318 CHAPTER 2Page 17Issue 1CIRCUIT CARD EXPLANATIONSFigure 2-7 Attachment of Sub Board (PZ-8VCTB) onto IPTRK Circuit CardTo "SUB3A"
CHAPTER 2 NDA-24318Page 18Issue 1CIRCUIT CARD EXPLANATIONS2.7 Switch Setting Sheet3. PZ-8VCTB (Sub Board)3.1 General Function/Mounting LocationPZ-8VCT
NDA-24318 CHAPTER 3Page 19Issue 1OFFICE DATA PROGRAMMINGCHAPTER 3 OFFICE DATA PROGRAMMING1. GENERALThis chapter explains the procedure to assign the I
CHAPTER 3 NDA-24318Page 20Issue 1OFFICE DATA PROGRAMMING2.1 Required HardwareThis feature is available using the following hardware. As shown, both si
NDA-24318 CHAPTER 3Page 21Issue 1OFFICE DATA PROGRAMMING2.2 Required Hardware (Point-to-Multipoint Connection)This feature (allowing IPTRK circuit car
CHAPTER 3 NDA-24318Page 22Issue 1OFFICE DATA PROGRAMMING2.3 Service Conditions1. To send/receive speech and CCIS signals, each node will use an IPTRK
ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4DATE NOVEMBER, 2000 DATE DATE DATEISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8DATE DATE DATE DATENEAX2400 IPXIPTRK Circuit Card Syst
NDA-24318 CHAPTER 3Page 23Issue 1OFFICE DATA PROGRAMMING6. Tandem Path through function is not provided.7. This feature supports QoS (Quality of Servi
CHAPTER 3 NDA-24318Page 24Issue 1OFFICE DATA PROGRAMMING11. This feature does not support Broad Band Services H0/H1. Therefore, when assigning the IPT
NDA-24318 CHAPTER 3Page 25Issue 1OFFICE DATA PROGRAMMINGFigure 3-3 Port Assignment of Bch for CCIS Tie LineNote 1:An IPTRK circuit card can be accom
CHAPTER 3 NDA-24318Page 26Issue 1OFFICE DATA PROGRAMMINGPerform the following data assignment using the ACSC/ACIC2 commands.Figure 3-4 Example Data
NDA-24318 CHAPTER 3Page 27Issue 1OFFICE DATA PROGRAMMING• In Point-to-Multipoint connection, because it cannot be determined which destination node is
CHAPTER 3 NDA-24318Page 28Issue 1OFFICE DATA PROGRAMMINGFigure 3-5 Example Assignment of IP Addresses of IPTRK Circuit Card and Connected RouterIPTR
NDA-24318 CHAPTER 3Page 29Issue 1OFFICE DATA PROGRAMMING3. FCCS NETWORKING VIA IP [F-36]This feature allows the system to exchange both speech and FCC
CHAPTER 3 NDA-24318Page 30Issue 1OFFICE DATA PROGRAMMING3.1 Required HardwareThis feature is available by using the following hardware. As shown, both
NDA-24318 CHAPTER 3Page 31Issue 1OFFICE DATA PROGRAMMING3.2 Required Hardware (Point-to-Multipoint Connection)This feature (allowing IPTRK circuit car
CHAPTER 3 NDA-24318Page 32Issue 1OFFICE DATA PROGRAMMING3.3 Service Conditions1. To send/receive voice information, each node will use an IPTRK circui
NDA-24318ISSUE 1NOVEMBER, 2000NEAX2400 IPXIPTRK Circuit Card System ManualTABLE OF CONTENTSPageNDA-24318 TABLE OF CONTENTSPage iIssue 1CHAPTER 1 INTRO
NDA-24318 CHAPTER 3Page 33Issue 1OFFICE DATA PROGRAMMING7. For Point-to-Multipoint connection, one IPTRK circuit card (assigned as FCCS signal control
CHAPTER 3 NDA-24318Page 34Issue 1OFFICE DATA PROGRAMMING13. When all lines of an IPTRK circuit card are busy, alternate routing to C.O. line or Tie li
NDA-24318 CHAPTER 3Page 35Issue 1OFFICE DATA PROGRAMMINGSTEP 2: ACRD - Assign Route Class Data of speech routes. It is not required to assign the sign
CHAPTER 3 NDA-24318Page 36Issue 1OFFICE DATA PROGRAMMINGSTEP 3: ACTK - Assign the connection trunk data of IPTRK circuit card. It is not required to a
NDA-24318 CHAPTER 3Page 37Issue 1OFFICE DATA PROGRAMMINGSTEP 5: AFCH - Assign FCH number (FCHN) to each IPTRK circuit card which is used as the FCCS s
CHAPTER 3 NDA-24318Page 38Issue 1OFFICE DATA PROGRAMMINGSTEP 6: AETH - Assign the following data:FPC (Fusion Point Code): FPC number (1-253) of the De
NDA-24318 CHAPTER 3Page 39Issue 1OFFICE DATA PROGRAMMINGSTEP 7: ACAN - Assign the Fusion Connection Index Code (FCIC) to Self node FPC:FPC (Fusion Poi
CHAPTER 3 NDA-24318Page 40Issue 1OFFICE DATA PROGRAMMINGSTEP 9: AGIP - Assign IP addresses of IPTRK circuit card and its connected route.LENS (Line Eq
NDA-24318 CHAPTER 3Page 41Issue 1OFFICE DATA PROGRAMMINGFigure 3-14 Example Assignment of IP Addresses of IPTRK Circuit Card and Connected RouterIPT
CHAPTER 3 NDA-24318Page 42Issue 1OFFICE DATA PROGRAMMING3.4.1 FCCS Routing Example Data SheetsThis figure represent example data for FCCS Networking v
LIST OF FIGURES NDA-24318Page iiIssue 1LIST OF FIGURESPageFigure 1-1 Example Network Configuration via Intranet . . . . . . . . . . . . . . . . . . .
NDA-24318 CHAPTER 3Page 43Issue 1OFFICE DATA PROGRAMMINGThis figure represent example data for FCCS Networking via IP [F-36].Figure 3-16 FCCS Networ
CHAPTER 3 NDA-24318Page 44Issue 1OFFICE DATA PROGRAMMINGThis figure represent example data when ASPC and AETH commands are required for an identical F
NDA-24318 CHAPTER 3Page 45Issue 1OFFICE DATA PROGRAMMINGThis figure represent example data when FCCS routing data is not assigned by using the AFPCcom
CHAPTER 3 NDA-24318Page 46Issue 1OFFICE DATA PROGRAMMINGThis figure represent example data when AFPC and AETH commands are required for an identical F
NDA-24318 CHAPTER 4Page 47Issue 1OPERATION TESTS AFTER INSTALLATIONCHAPTER 4 OPERATION TESTS AFTER INSTALLATION1. GENERALThis chapter explains the pro
CHAPTER 4 NDA-24318Page 48Issue 1OPERATION TESTS AFTER INSTALLATION1. Test of IP-LINK lamp on IPTRK circuit card: NoteNote:H.323 Handler (PA-8IPTB-A).
NDA-24318 CHAPTER 4Page 49Issue 1OPERATION TESTS AFTER INSTALLATION3. FCCS NETWORKING VIA IP [F-36]When using the IPTRK circuit card for FCCS Networki
CHAPTER 4 NDA-24318Page 50Issue 1OPERATION TESTS AFTER INSTALLATION3. Test of IP-LINK lamp on IPTRK circuit card:a.) See if the IP-LINK lamp on the IP
NDA-24318 LIST OF TABLESPage iiiIssue 1LIST OF TABLESPageTable 1-1 Specification of IP Trunk . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIST OF TABLES NDA-24318Page ivIssue 1This page is for your notes.
NDA-24318 CHAPTER 1Page 1Issue 1INTRODUCTIONCHAPTER 1 INTRODUCTION1. GENERALThis manual explains the installation of the following IPTRK circuit cards
CHAPTER 1 NDA-24318Page 2Issue 1INTRODUCTIONNote 1: Transmission speed is within 14.4 kbps.Note 2: On a conference call via IPTRK, Echo Canceller cann
Comments to this Manuals