Chapter 6: Advanced Chassis Setup
6-9
6-5 Power Supply
5015M-UR/5015M-NTR
The Series3800/S110R-1 (5015M-UR/5015M-U/5015M-NTR/5015M-NT) has a 450
watt redundant power supply con guration consisting of two hot-swap power mod-
ules. The power supply modules have an auto-switching capability, which enables
them to automatically sense and operate with a 100V - 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The Univer-
sal Information LED on the control panel will blink red slowly and remain so until
the failed module has been replaced. Replacement modules can be ordered. The
power supply modules have a hot-swap capability, meaning you can replace the
failed module without powering down the system.
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply module. The
redundant feature will keep the system up and running while you replace the failed
hot-swap module. Replace with the same model.
1. Removing the power supply
First unplug the power cord from the failed power supply module. To remove the
failed power module, push the release tab (on the back of the power supply) to
the side and then pull the module straight out (see Figure 6-6). The power supply
wiring was designed to detach automatically when the module is pulled from the
chassis.
2. Installing a new power supply
Replace the failed power module with another PWS-451-1R power supply module.
Simply push the new power supply module into the power bay until you hear a click.
Finish by plugging the AC power cord back into the module.