5-12 Problem Solving
Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message Explanation Action
0B33 Fan 4 Alarm occurred. CPU cooling fan error Same as above
0B34 Fan 5 Alarm occurred. CPU cooling fan error Same as above
0B35 Fan 6 Alarm occurred. CPU cooling fan error Same as above
0B36 Fan 7 Alarm occurred. Optional board cooling fan error Same as above
0B40 Invalid System Configuration Data System configuration data is
damaged.
Start the Setup Utility to set
the time again. If the same
error reoccurs, contact your
service representative.
0B41 System Configuration Data Read
error
Read error on the data
configuring the system
Ask your service
representative for System I/O
board replacement.
0B42 Resource Conflict The PCI board resource is not
properly mapped.
Start the Setup Utility for
reset. If the same error
reoccurs, contact your
service representative.
0B43 WARNING: IRQ not configured The PCI board interrupt is not
properly set.
Same as above.
0B44 Expansion ROM not initialized The expansion ROM on the PCI
board is not initialized.
Check PCI board installation.
If the same error reoccurs,
ask your service
representative for System I/O
board replacement.
0B45 System Configuration Data Write
Error
Write error on the data
configuring the system.
Ask your service
representative for System I/O
board replacement.
0B50 CPU#1 with error taken off line. Because an error was detected
in CPU #1, it was disabled.
The CPU is disabled. Contact
your service representative.
0B51 CPU#2 with error taken off line. Because an error was detected
in CPU #2, it was disabled.
Same as above.
0B52 CPU#3 with error taken off line. Because an error was detected
in CPU #3, it was disabled.
Same as above.
0B53 CPU#4 with error taken off line. Because an error was detected
in CPU #4, it was disabled.
Same as above.
0B54 CPU#5 with error taken off line. Because an error was detected
in CPU #5, it was disabled.
Same as above.
0B55 CPU#6 with error taken off line. Because an error was detected
in CPU #6, it was disabled.
Same as above.
0B56 CPU#7 with error taken off line. Because an error was detected
in CPU #7, it was disabled.
Same as above.
0B57 CPU#8 with error taken off line. Because an error was detected
in CPU #8, it was disabled.
Same as above.
0B58 Forced to use CPU#1 with error An error was detected in CPU#1. The system is started forcibly
though an error is detected in
the CPU displayed. Contact
your service representative.