NEC Express5800/320Lb Linux User's Guide

Browse online or download User's Guide for Software NEC Express5800/320Lb Linux. NEC Express5800/320Lb Linux User's Guide User Manual

/ 296
Table of contents
Troubleshooting
N8800-057F/058F

NEC Express5800/320Lb/320Lb-R

User's Guide

1st Edition
4-2005
856-125249-901-A

PDF file · ·

Print

Print document

Sharing

Summary of Contents

Page 1 - User's Guide

N8800-057F/058F NEC Express5800/320Lb/320Lb-R User's Guide 1st Edition 4-2005 856-125249-901-A

Page 2

PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable…

Page 3 - SAFETY INDICATIONS

Keep this User's Guide handy for quick reference when necessary. SAFETY INDICATIONS To use NEC Express5800 Series safely, follow the instructions in…

Page 4 - Mandatory actions

SYMBOLS USED IN THIS USER'S GUIDE AND WARNING LABELS Attention Indicates a risk of an electric shock. Indicates a risk of an injury due to heat.…

Page 5

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These…

Page 6 - To prevent voltage sag:

Trademarks NEC ESMPRO, NEC EXPRESSBUILDER, and NEC Express5800/ft series are trademarks of NEC Corporation. Microsoft, Windows, Windows NT, and MS-DOS…

Page 7 - PREFACE

i PREFACE Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a “fault-tolerant (ft)” server focusing on “high reliability” in…

Page 8 - ABOUT THIS USER'S GUIDE

ii ABOUT THIS USER'S GUIDE This User's Guide helps a user to properly setup and use the product. Consult this guide to ensure safety as well as to…

Page 9 - Accessories

iii Additional symbols The following symbols are used throughout this User's Guide in addition to the caution symbols describe at the beginning.…

Page 10

iv (This page is intentionally left blank.)

Page 11 - CONTENTS

v CONTENTS PREFACE i ABOUT THIS USER'S GUIDE ii Chapter 1 Precautions for Use 1-1 WARNING LABELS 1-2 Tower Model 1-2 Rack-mount Model 1-4 PCI/CPU…

Page 12

vi Chapter 4 System Configuration 4-1 SYSTEM BIOS ~ SETUP ~ 4-2 Starting SETUP Utility 4-3 Description of On-Screen Items and Key Usage 4-4…

Page 13

vii Chapter 7 Troubleshooting 7-1 TO LOCATE THE ERRORS 7-2 ERROR MESSAGES 7-3 Error Messages by LED Indication 7-3 Error Messages on the Liquid…

Page 14

viii Setup of Optional PCI Board 8-43 Appendix A Specifications A-1 Appendix B I/O Port Address B-1

Page 15 - Chapter 1

Chapter 1 Precautions for Use This chapter includes information necessary for proper and safe operation of the server.

Page 16 - WARNING LABELS

WARNING LABELS Warning labels are placed in certain parts of the system so that the user stays alert to possible risks (Do not remove or damage these…

Page 17 - Label E

Label A Label D Label C Label B Label E

Page 18 - Rack-mount Model

Rack-mount Model Label B Label C Label E Label D Label A

Page 19

Label A Label B Label C Label D Label E

Page 20 - PCI/CPU Modules

PCI/CPU Modules PCI Module Label A External View Label B Internal View CPU Module Label A External View

Page 21

Label B Internal View Label A Label B

Page 22 - PRECAUTIONS FOR SAFETY

PRECAUTIONS FOR SAFETY This section provides precautions for using the server safely. Read this section carefully to ensure proper and safe use of the…

Page 23

Use of Power Supply and Power Cord WARNING Do not handle a power plug with a wet hand. Do not plug/unplug a power cord with a wet hand. There is a…

Page 24

Installation, Relocation, Storage and Connection WARNING Disconnect the power cord(s) before installing or removing the equipment. Be sure to power…

Page 25

CAUTION Do not use any non-designated interface cable. Use only interface cables designated by NEC; identify which component or connector to attach…

Page 26

Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, never attempt to…

Page 27 - During Operation

During Operation CAUTION Do not pull out a device during operation. Do not pull out or remove a device while it works. There is a risk of malfunction…

Page 28

Rack-mount Model CAUTION Do not install the equipment on a nonconforming rack. Install the equipment on a 19-inch rack confirming to the EIA standard.…

Page 29 - For Proper Operation

For Proper Operation Observe the following instructions for successful operation of the server. Failure to observe them could lead to malfunction or…

Page 30

Make sure that your options are compatible with the system. If you attach any incompatible option, there is a risk of malfunction that could lead to a…

Show all 296 pages
Page 31 - TRANSFER TO THIRD PARTY

TRANSFER TO THIRD PARTY When you transfer (or sell) the product or its included items, you must observe the following: Server Attach this User's Guide…

Page 32

DISPOSAL OF EQUIPMENT AND CONSUMABLES When you dispose of the main unit, hard disk drive, floppy disks, CD-ROMs, optional boards, etc., you need to…

Page 33 - ABOUT REPAIR PARTS

IF SYSTEM TROUBLE IS SUSPECTED Before sending the equipment for repair, try the following: 1. Check if its power cord and connection cables are…

Page 34 - Advice for Your Health

Advice for Your Health Prolonged use of a computer may affect your health. Keep in mind the following to reduce stresses on your body: Sit in a good…

Page 35 - Chapter 2

Chapter 2 General Description This chapter describes what you need to know to use the NEC Express5800/ft series. Refer to this chapter when you want…

Page 36 - STANDARD FEATURES

STANDARD FEATURES High performance Intel Xeon Processor (2.4 GHz) High-speed Ethernet interface (1000Mbps/100Mbps/10Mbps supported) High-speed disk…

Page 37

The NEC Express5800/ft series achieves fault-tolerant high-availability in a space-saving form factor by incorporating redundant hardware module pairs…

Page 38

NEC Express5800/ft series mainly provides the following advantages: Highly fault-tolerant processing and I/O subsystems NEC Express5800/ft series use…

Page 39 -  In-service repairing

Local and remote management NEC Express5800/ft series uses NEC ESMPRO as a server management tool. This tool uses a GUI that enables monitoring and…

Page 40 - Front View

NAMES AND FUNCTIONS OF COMPONENTS Names and functions of components are shown below: Front View Tower model Rack-mount model

Page 41

1 Front bezel A door that covers internal components. You can lock it with the included security key. 2 Key slot Insert the security key in this slot…

Page 42 - Front View (inside)

Front View (inside) Tower model Rack-mount model

Page 43 - CD- ROM Drive

1 PCI module (for group 1) A module that includes a PCI board and LAN controller. 2 PCI module (for group 2) A module that includes a PCI board and…

Page 44 - Rear View

Rear View CPU module ( for Grou p 1 ) CPU module ( for Grou p 2 ) PCI module (for Group1) Tower model PCI module ( for Grou p 2 ) PCI module ( for…

Page 45

1 Serial port A connector Connected to a device that has a serial interface. For maintenance use only. 2 AC inlet B (for Group1) PC socket for…

Page 46 - CPU Module

CPU Module Group 1 and group 2 have the same configuration. 1 Module handle 2 Cooling fan 3 CPU module board 4 CPU socket #2 (additional) 5 AC inlet…

Page 47

CPU module board Group 1 and group 2 have the same configuration . 1 Cooling fan connector 2 LED connector 3 Power connector 4 CPU socket #2 5 CPU…

Page 48 - PCI Module

PCI Module Group 1 and group 2 have the same configuration. 1 Cooling fan 2 Power unit 3 AC inlet (in the back) The AC cable in the module which is…

Page 49 - Chassis Board Layout

PCI module board Group 1 and group 2 have the same configuration. 1 SCSI connector (external) 2 Configuration jumper pin 3 Battery (lithium battery) 4…

Page 50 - BMC Status LED

LEDs This section describes indications and meanings of the LEDs on NEC Express5800/ft series. Refer to pages 2-6 through 2-11 for the locations of…

Page 51

LED indications Primary Secondary Description Action Detected a fatal temperature error. If LCD displays some error message, refer to the error…

Page 52

LED indications Primary Secondary Description Action BMC is being dumped. Wait for a while. After a while, the BMC status LED on the primary will go…

Page 53 - Disk Access LED

PCI Module Status LEDs 1/2 Disk Access LED The PCI module has three LEDs. Combined, the three LEDs show the status of the PCI modules and hard disks.…

Page 54

PCI#1 PCI#2 Status LED 2 DISK Access LED Status LED 2 DISK A ccess LED Description Action Green Green/ Off * Amber Green/ Off * i) There is an error…

Page 55

(2) Status LED 1 of both PCI modules are red PCI#1 PCI#2 Status LED 2 DISK Access LED Description Action Off Off On standby (AC power is supplied…

Page 56

PCI#1 PCI#2 Status LED 2 DISK Access LED Description Action Green Off Off Off The PCI module 1 is performing diagnosis (Diag). AC power is not…

Page 57 - The CPU module has two LEDs

CPU Module Status LEDs 1/2 The CPU module has two LEDs. Combined, the two LEDs show the status of CPU modules: See “NAMES AND FUNCTIONS OF COMPONENTS”…

Page 58

CPU#1 CPU#2 Status LED1 Status LED2 Description Action Off Amber Off Off AC power is not supplied to the CPU module 2. The CPU module 1 operates in…

Page 59 - DISK LED

PCI Board Slot Status LEDs (P1, P2, P3) To show the status of PCI board slots, each PCI module has three status LEDs. LED indications Description…

Page 60

TIPS: When there are many accesses, the access LED will blink frequently. Check if the LED blinks in green when the number of accesses decreases, or…

Page 61 - LAN Connector LEDs

LAN Connector LEDs Two LAN ports (connectors) located in the back have two LEDs each. 100/10 LED (LAN connector 2), 1000/100/10 LED (LAN connector 1)…

Page 62 - BASIC OPERATION

BASIC OPERATION This section describes basic operation procedures of NEC Express5800/ft series. Locking and Unlocking the Front Bezel The front bezel…

Page 63 - Tabs Frame

Rack-mount Model The rack-mount model server is equipped with a detachable front bezel. Detach Follow the steps below to detach the front bezel: 1.…

Page 64 - Power ON

Power ON To power on NEC Express5800/ft series, press the POWER switch located on the front panel. Follow the steps below to turn on the power. (A…

Page 65 - Power OFF

Power OFF Follow the steps below to turn off the power. If NEC Express5800/ft series is plugged to a UPS, see manuals included with the UPS or the…

Page 66 - POST Check

POST Check POST (power-on self test) is a self-test function stored on the motherboard of NEC Express5800/ft series. When you power on the server…

Page 67

Flow of POST This section walks you through how POST is performed. 1. When you power on the system, one selected CPU/PCI module will start up. POST…

Page 68 -  Makes a beeping sound

Upon completion of POST, the password entry screen appears prior to OS startup. The password entry screen will appear after the normal termination of…

Page 69 - Floppy Disk Drive

Floppy Disk Drive A USB floppy disk drive is attached to the main unit. It allows you to read and write (save) data using floppy disks. The USB floppy…

Page 70 - Use of Floppy Disk

Use of Floppy Disk You may need to store important data on floppy disks. Since the floppy disk is a very delicate medium, you must handle it with…

Page 71 - CD-ROM Drive

CD-ROM Drive NEC Express5800/ft series has a CD-ROM drive on the front panel. It is a device used to read data from a CD-ROM (compact disc read-only…

Page 72 - Use of CD-ROM

Use of CD-ROM Observe the following when you use a CD-ROM on NEC Express5800/ft series: As for a disk such as a noncompliant “copy-protected CD,” we…

Page 73 - Chapter 3

Chapter 3 Linux Setup and Operation This chapter describes setup procedures to make NEC Express5800/ft series ready for use.

Page 74

2 Linux Setup and Operation HARD DISK CONFIGURATIONS THAT CAN BE BUILT ON THE NEC Express5800/ft series In the NEC Express5800/ft series, all built-in…

Page 75 - RAID by software

Linux Setup and Operation 3-3 Perform operations for built-in SCSI disks, such as mounting a disk, to devices (md) for RAID by software. With the…

Page 76 - How to Locate Failed Disks

4 Linux Setup and Operation REPLACING 3.5-INCH HARD DISK DRIVE Follow the procedure below to remove the failed hard disk. If the hard disk fails, it…

Page 77

Linux Setup and Operation 3-5 3. See the path information in [General Information] of [SCSI Slot (ID: 41/1)]. It shows that PCI module, SCSI adapter…

Page 78

6 Linux Setup and Operation Restoring Redundant Configuration Manually This section describes procedure to change the built-in disk on which failures…

Page 79

Linux Setup and Operation 3-7

Page 80

8 Linux Setup and Operation <<Confirm that the disk is disconnected>> <<Confirm that the above status is SIMPLEX before exchanging the disk>> <<The…

Page 81

Linux Setup and Operation 3-9 <<Confirm that the duplication process is started >> <<Perform RESYNC to each md device. After a while, use the…

Page 82

10 Linux Setup and Operation (This page is intentionally left blank.)

Page 83 - Chapter 4

Chapter 4 System Configuration This chapter describes Basic Input Output System (BIOS) configuration. When you install the server for the first time…

Page 84 - SYSTEM BIOS ~ SETUP ~

SYSTEM BIOS ~ SETUP ~ The SETUP utility is provided to make basic hardware configuration for the server. This utility is pre-installed in the flash…

Page 85 - Starting SETUP Utility

Starting SETUP Utility Powering on the server starts POST (Power On Self-Test) and displays its check results. If the NEC logo is displayed, press…

Page 86

Description of On-Screen Items and Key Usage Use the following keyboard keys to work with the SETUP utility. (Key functions are also listed at the…

Page 87 - Configuration Examples

Configuration Examples The following describes examples of configuration required to use software-link features or for system operations. Link with…

Page 88 - Optional PCI–related devices

Security To set passwords on the BIOS level Select [Security] [Set Supervisor Password] and enter a password. Set Supervisor password first, then User…

Page 89

Memory To check the installed memory (DIMM) status Select [Advanced] [Memory Information] and check the status indications. Saving the Configuration…

Page 90

Menu and Parameter Descriptions The SETUP utility has the following six major menus: Main Advanced Security System Hardware Boot Exit To configure…

Page 91

Available options in the Main and descriptions are listed below. Option Parameter Description Your Setting Processor Type Intel® Xeon™ Processor…

Page 92

Advanced Move the cursor onto "Advanced" to display the Advanced menu. Advanced Processor Information Memory Information Peripheral Configuration…

Page 93 - Select Menu

Advanced Select "Advanced" on the Advanced menu to display the following screen. Select Item Select Menu upport: iagnostic enabled. F9 Setup Defaults…

Page 94

Processor Information Select "Processor Information" on the Advanced menu to display the following screen. Processor 1 Type: Processor 2 Type: Item…

Page 95

Memory Information Select "Memory Information" on the Advanced menu to display the following screen. See the table below for setup options on the…

Page 96

Peripheral Configuration Select "Peripheral Configuration" on the Advanced menu to display the following screen. Phoenix BIOS Setup Utility Advanced…

Page 97 - Monitoring Configuration

Monitoring Configuration Select "Monitoring Configuration" on the Advanced menu to display the following screen. Option ROM Scan Monitoring: Option…

Page 98

Option Parameter Description Your Setting POST Pause Monitoring Time-out 1 - [3] - 20 Specify the POST monitoring time period during boot-up…

Page 99 - “Disabled”

See the table below for setup options on the screen. Option Parameter Description Your Setting On Board SCSI Disabled [Enabled] Enable or disable…

Page 100

Keyboard Features Select "Keyboard Features" on the Advanced menu to display the following screen. The NumLock submenu allows you to make keyboard…

Page 101

Security Move the cursor onto "Security" to display the Security menu. Phoenix BIOS Setup Utility Exi t Boo t System HardwareritySecuAdvancedMain Item…

Page 102 - IMPORTANT:

IMPORTANT: User password setup is not available before Supervisor password setup. Do not set any password before installing the OS. See the table…

Page 103 - System Hardware

System Hardware Move the cursor onto "System Hardware" to display the System Hardware menu. To make a selection for "Thermal Sensor", "Wake On Event"…

Page 104

The table below lists how selections for "AC LINK" determine the power status of the server when the power supply to the server restarts. Parameter…

Page 105

Wake On Events Select "Wake On Events" on the System Hardware menu and press Enter to display the following screen. Wake On LAN: Enables Wake On LAN…

Page 106

Console Redirection Select "Console Redirection" on the System Hardware menu and press Enter to display the following screen. Serial Port Address…

Page 107

ft Memory Select "ft Memory" on the System Hardware menu and press Enter to display the following screen. See the table below for setup options on the…

Page 108

Boot Move the cursor onto "Boot" to display the Boot menu. Phoenix BIOS Setup Utility Exit Boo t ardwareSystem HritySecuAdvancedMain Item Specific…

Page 109 -  Save Changes & Exit

Exit Move the cursor onto "Exit" to display the Exit menu. Save Changes & Exit Exit Without Saving Changes Get Default Value Load Previous Value Save…

Page 110 -  Save Changes

Get Default Value Select this option to restore all default values (factory-set values) of the SETUP utility. The following screen appears: Load…

Page 111 - SCSI BIOS ∼ FAST!UTIL ∼

SCSI BIOS FAST!UTIL For several settings of the SCSI controller on the motherboard, the SCSI BIOS utility "Fast!UTIL" is used. The SCSI BIOS utility…

Page 112

Start Procedure Start Fast!UTIL in the procedure below: 1. Turn on the power of the server. The start message appears on a screen in the middle of…

Page 113

Select the proper adapter. IMPORTANT: The adapter "QLA12160 Ultra3 2000" is used for built-in hard disk. Do not select it. Highlight the displayed…

Page 114 - Configuration Settings

Configuration Settings If you select "Configuration Settings" from the "Fast!UTIL Options" menu, the screen for setting the configuration appears.…

Page 115 - 00, 02, 04, 06, 08

SCSI Device Settings If you put the cursor on "SCSI Device Settings" with keyboard cursors ( and ) in the "Configuration Settings" menu and press…

Page 116

SCSI Bus Settings If you put the cursor on "SCSI Bus Settings" with keyboard cursors ( and ) in the "Configuration Settings" menu and press Enter, the…

Page 117

Selectable Boot Settings If you put the cursor on "Selectable Boot Settings" with keyboard cursors ( and ) in the "Configuration Settings" menu and…

Page 118 - Select Host Adapter

Scan SCSI Bus If you select "Scan SCSI Bus" from the "Fast!UTIL Options" menu, the list of devices connected to each SCSI bus is displayed in the…

Page 119 - Exit Fast!UTIL

Exit Fast!UTIL Termination and Storage of Fast!UTIL After changing the settings, press Esc several times to display the "Fast!UTIL Options" menu. If…

Page 120 - FORCED SHUTDOWN AND CLEAR

FORCED SHUTDOWN AND CLEAR Read this section if your server does not operate as expected, or if you want to return all setup values to those made at…

Page 121

Clear CMOS / Password (Configuring Motherboard Jumpers) With the pre-installed SETUP utility, you can set desired passwords to protect data stored on…

Page 122

Pins for protecting/clearing the passwords Place the clip on the two pins to clear the passwords. Remove the clip from these pins to protect the…

Page 123

TIPS: A message informing you of the completion of CMOS clear and prompting you to clear CMOS will appear for 10 seconds. Note that even if you do not…

Page 124 - CHECK:

Shortly after you connect the both power cords, the BMC status LED of PCI Module #2 will start to blink. When the BMC status LED goes off, the clear…

Page 125

How to Clear Passwords 1. Power off NEC Express5800/ft series and unplug the both power cords. 2. Remove the both PCI modules (#1 and #2) from the NEC…

Page 126

Mount the PCI Module #1 again to the NEC Express5800/ft series (see page 8-33 “Installing PCI Module”) and plug the power cord to the AC inlet B (for…

Page 127 - Chapter 5

Chapter 5 Installing and Using Utilities This section describes how to use the NEC EXPRESSBUILDER CD-ROM that comes with your server and to install…

Page 128 - NEC EXPRESSBUILDER

NEC EXPRESSBUILDER The NEC EXPRESSBUILDER, integrated setup software, can automatically detect the hardware connected to an NEC Express5800/ft series…

Page 129

IMPORTANT: Don’t use this CD-ROM on computers other than NEC Express5800/ft series with which it is packaged (including other NEC Express5800 models).…

Page 130 - NEC EXPRESSBUILDER Top Menu

NEC EXPRESSBUILDER Top Menu The NEC EXPRESSBUILDER top menu is used for the setup of hardware and the setup and installation of OS. Start Start the…

Page 131

Tools The Tools Menu is used to start each of the several utilities stored in the NEC EXPRESSBUILDER CD-ROM individually for manual setup by operator.…

Page 132 -  Return to the Top Menu

BIOS/FW/etc. Update The program which is necessary for the update work is transferred to the floppy disk which the various update modules of BIOS/FW…

Page 133 - Consoleless Menu

Consoleless Menu The NEC EXPRESSBUILDER contains the "consoleless" feature that enables configuration of the server by remote operation from the…

Page 134 - Menu Items

Menu Items Only the menu items available in consoleless operation are extracted from the NEC EXPRESSBUILDER Top Menu. See the NEC EXPRESSBUILDER Top…

Page 135 - Master Control Menu

Master Control Menu Load the attached “NEC EXPRESSBUILDER” CD-ROM in the CD-ROM drive of the computer that runs Windows (Windows 95 or later, or…

Page 136 - NEC ESMPRO Agent and Manager

NEC ESMPRO Agent and Manager NEC Express5800/ft series system management applications "NEC ESMPRO Manager" is bundled to accessory CD-ROM "NEC…

Page 137 - − Detection of server fault

Effects of using NEC ESMPRO Manager and Agent NEC ESMPRO Manager and NEC ESMPRO Agent have sufficient effects on a variety of needs in versatile and…

Page 138 - Prevention of Server Fault

Detection of Server Fault NEC ESMPRO Manager and NEC ESMPRO Agent detect errors causing faults to occur at an early stage and notify Administrators of…

Page 139

Management of Server Operation Status NEC ESMPRO Agent manages and monitors a variety of components installed in the server. You can view the…

Page 140

Function name Supported Function description Storage Function to monitor storage devices (e.g., hard disk drive) and controller File system Function…

Page 141

Monitoring of NEC Express5800/ft series is a fault tolerant system. It can continue the operation even if a major component fails. NEC Express5800/ft…

Page 142 -  Operation Window

. Collective Management of Distributed Servers The excellent GUI provided by NEC ESMPRO Manager allows servers on a network to be managed…

Page 143 -  Alert Viewer

Data Viewer The data viewer indicates the server source configuration information in the Explorer format. In addition, it changes the status color of…

Page 144 - NEC ESMPRO Agent

NEC ESMPRO Agent Device ID in Alert Report Some NEC Express5800/ft series reports use unique device IDs which correspond to the devices listed in the…

Page 145

Device name Device ID SCSI enclosure 2 SCSI slot 1 on SCSI enclosure 2 SCSI slot 2 on SCSI enclosure 2 SCSI slot 3 on SCSI enclosure 2 Electronics 1…

Page 146 - Supplement

Supplement Note the following when using NEC ESMPRO Agent. Maintenance-related Functions When you want to use maintenance-related functions of the NEC…

Page 147

To enable the remote shutdown and threshold change functions via NEC ESMPRO Manager, make settings of community and set its authority to "READ CREATE"…

Page 148

When [ft Server] Tree Appears on a Data Viewer in an Incorrect Manner If you perform a Data Viewer startup or tree rebuilding just after the system…

Page 149 - NEC ESMPRO Manager

NEC ESMPRO Manager To monitor and manage a computer, on which NEC ESMPRO Agent is installed, with a management PC online, use NEC ESMPRO Manager that…

Page 150 -  Maintenance

Monitoring CPU Module To monitor the CPU modules and the components on the CPU module, see the [CPU Module] tree. To see the information on the [CPU…

Page 151 -  DIMM

Update Allows the device identification information of the CPU modules to be viewed and BIOS of the CPU modules to be updated. See "Maintenance of NEC…

Page 152

Monitoring PCI Module To monitor the PCI modules and the components on the PCI modules, refer to the [PCI Module] tree. To see the information on the…

Page 153 -  PCI Device – General

Monitoring PCI Slots and Devices on PCI Module To monitor the PCI slots and devices on the PCI modules, see the [PCI slot] tree. To see the…

Page 154

PCI Device – Detailed information Allows the detailed information of a device on the PCI slot to be viewed.

Page 155

Monitoring SCSI Adapter on PCI Module To monitor the SCSI adapter on the PCI modules, see the [SCSI adapter] tree. To see the information on the [SCSI…

Page 156

Monitoring BMC on PCI Module To monitor the base management controller (BMC), controller for system management, on the PCI modules, see the [BMC]…

Page 157 -  Detailed

Monitoring Ethernet Adapter on PCI Module To monitor the Ethernet adapter on the PCI modules, see the [Ethernet adapter] tree. To see the information…

Page 158

Maintenance Allows the MTBF information of the Ethernet adapter to be viewed or cleared. See "Maintenance of NEC Express5800/ft series" described…

Page 159

Monitoring SCSI Enclosure To monitor the SCSI enclosure, see the [SCSI enclosure] tree. To see the information on the [SCSI enclosure] tree, select…

Page 160 -  SCSI Slot – General

Electronics – General Allows the configuration and other information of the SCSI enclosure electronics to be viewed. Electronics – Maintenance Allows…

Page 161 - [Mirror Disk]

SCSI Slot – Maintenance Allows the MTBF information of the SCSI slot to be viewed or cleared. See "Maintenance of NEC Express5800/ft series" described…

Page 162 - 3. Start the tool

Maintenance of NEC Express5800/ft series maintenance can be done in two ways; one is to use NEC ESMPRO Manager for remote maintenance and the other is…

Page 163 - ESMPRO

The table below shows the component-specific maintenance functions executable from NEC ESMPRO. Dump acquisition during system operation Board switch…

Page 164 - Start and Stop of Components

Start and Stop of Components To start or stop a component with NEC ESMPRO Manager, use the [Maintenance] tree of the component in the [FTServer] tree…

Page 165

Procedure in NEC ESMPRO Manager Start 1. Select the target component in the [FTServer] tree. 2. Check the current state with the "Status" display on…

Page 166

Sample screen of NEC ESMPRO Manager 2 [Maintenance] screen of CPU module [CPU Module] – [Maintenance]

Page 167 - Main window

Procedure in the ft server utility Start 1. Select the target component from the main window of the ft server utility. The screen of the target…

Page 168

Check and Clear of MTBF Information The MTBF information of a component can be viewed or cleared (initialized). NEC Express5800/ft series manages the…

Page 169 - 4. Start the component

MTBF clear Component Remote Local SCSI Enclosure To start the module/component forcibly after replacing a module or if MTBF became lower than the…

Page 170

Procedure in the ft server utility Perform the procedure below before replacement of a component. 1. Select the target component from the main window…

Page 171 - Firmware Update

Firmware Update NEC Express5800/ft series can update firmware (including BIOS) if some hardware components operate in the online state (in which the…

Page 172

Procedure in the ft server utility 1. Enable “Auto module start” and “Auto firmware update”. See “Setup of System Operation” in this chapter for the…

Page 173 - [Firmware Update] screen

Sample screen of ft server utility Main window [CPU module] screen [Firmware Update] screen Even if you do not have the image data of firmware for…

Page 174 - Dump Collection

Dump Collection To collect the dump file with NEC ESMPRO Manager, use [CPU Module] [Maintenance] tree in the data viewer. To collect the dump with the…

Page 175 - [CPU Module] – [Maintenance]

Procedure in NEC ESMPRO Manager The [Dump] button of NEC ESMPRO Manager performs the function of "saving dump during system operation." 1. Select [CPU…

Page 176

Procedure in the ft server utility 1. On the main window of the ft server utility, select the target component. The screen of the target component…

Page 177 - Setup of System Operation

Setup of System Operation The following properties can be set as the operation setup of the whole system. Quick dump If this property is enabled (by…

Page 178 - 3. Click [Execute]

Configure the system settings using the ft server utility in the following procedure. The system cannot be configured using the NEC ESMPRO Manager. 1.…

Page 179 - BMC Firmware Update

BMC Firmware Update The firmware of the BMC on the PCI module can be updated. The base management controller (BMC) is the processor exclusively used…

Page 180 - 2. Click [Update]

Procedure of Update from the ft server utility Update the firmware in the procedure as follows. 1. Select [Firmware] on the main window of the ft…

Page 181

Changing Update Data Storage Destination Change the storage destination by using the ft server utility in the procedure below. 1. Select [Firmware] on…

Page 182

NEC MWA MANAGEMENT WORKSTATION APPLICATION NEC MWA is an application that enables the remote management of the server through a management PC over the…

Page 183

Remote Management Configuration for the Server without Console If the main unit does not have a console such as keyboard, you can operate tools on the…

Page 184

[Configuration for ft Series] dialog box, specify/register configuration information including the names of computers to be managed, and then write…

Page 185

Power off and on the main unit to reboot the system. After one reboot, the main menu will appear on the management PC’s screen, on which you can…

Page 186

Connect from the Management PC Directly Linked (through Serial port B) On the management PC that is linked directly to Serial port B of the main unit…

Page 187

Power off and on the main unit to reboot the system. After one reboot, the main menu will appear on the management PC’s screen, on which you can…

Page 188

(This page is intentionally left blank.)

Page 189 - Chapter 6

Chapter 6 Maintenance This chapter describes the daily maintenance of NEC Express5800/ft series and precautions when relocating or storing the server.

Page 190 - DAILY MAINTENANCE

2 Maintenance DAILY MAINTENANCE To use your NEC Express5800/ft series in best condition, check and maintain regularly as described below. If an error…

Page 191 - Cleaning

Maintenance 6-3 Making Backup Copies NEC recommends you make backup copies of your valuable data stored in hard disks of the server on a regular…

Page 192 - Rollers

4 Maintenance 7. Wipe the server with a dry cloth. 8. Wipe off dust from the fan exhaust opening on the rear of the server with a dry cloth. Cleaning…

Page 193

Maintenance 6-5 Cleaning the Floppy Disk Drive A read/write error may occur due to stains on the read/write head of the floppy disk drive. Use the…

Page 194 - Cleaning Tape Drive

6 Maintenance Cleaning Tape Drive Dirt on the tape head may be a cause of unsuccessful backup and damage to tape cartridge. Clean the tape head…

Page 195 - SYSTEM DIAGNOSTICS

Maintenance 6-7 SYSTEM DIAGNOSTICS The System Diagnostics runs several tests on the server. Select [Tools] [System Diagnostics] in the NEC…

Page 196 - Title bar

8 Maintenance 6. Select [System Diagnostics]. CURSOR: Select Window ENTER: View Window P: Log Out Q: Quit Target scope Test window System bar Title…

Page 197 - OFF-LINE MAINTENANCE UTILITY

Maintenance 6-9 OFF-LINE MAINTENANCE UTILITY The Off-line Maintenance Utility is an OS-independent maintenance program. When you are unable to start…

Page 198 -  System Information Viewer

10 Maintenance System Information Viewer Provides the functions to view information on the processor (CPU) and the BIOS and export it to a text file.…

Page 199

Maintenance 6-11 RELOCATING/STORING THE NEC Express5800/ft series Follow the procedure below to relocate or store the server. (Users should not…

Page 200

12 Maintenance 8. Carry the backplane, rails and modules separately. IMPORTANT: If the server is a tower model, do not hold the front bezel to lift…

Page 201 - Chapter 7

Chapter 7 Troubleshooting If the product does not work properly, see this chapter before deciding that it is a breakdown.

Page 202

TO LOCATE THE ERRORS Use NEC ESMPRO to monitor the occurrence of fault during the system operation. Especially take note on whether any alert is…

Page 203 - ERROR MESSAGES

ERROR MESSAGES If the NEC Express5800/ft series enters the abnormal state, the error is posted by various means. This section explains the types of…

Page 204

STATUS LED Indication Color State Suspected module Explanation Procedure = A = AmbientTempAlm 00 Amber Blink CPU module Temperature alarm (lower…

Page 205

STATUS LED Indication Color State Suspected module Explanation Procedure Cor0 +5.0vAlm 09 Amber Lit PCI module #1 Fatal 5-V power voltage alarm (upper…

Page 206

STATUS LED Indication Color State Suspected module Explanation Procedure Cor1 +12vAlm 00 Amber Blink PCI module #2 12-V power voltage alarm (lower…

Page 207

STATUS LED Indication Color State Suspected module Explanation Procedure Cor1 -12vAlm 07 Amber Blink PCI module #2 -12-V power voltage alarm (upper…

Page 208

STATUS LED Indication Color State Suspected module Explanation Procedure CPU0 +12ss Alm 07 Amber Blink CPU module #1 +12-V power voltage alarm (upper…

Page 209

STATUS LED Indication Color State Suspected module Explanation Procedure CPU0 +5.0vAlm 07 Amber Blink CPU module #1 5-V power voltage alarm (upper…

Page 210

STATUS LED Indication Color State Suspected module Explanation Procedure CPU00 Temp Alm 00 Amber Blink CPU module #1 CPU#1 temperature alarm (lower…

Page 211

STATUS LED Indication Color State Suspected module Explanation Procedure CPU2 +2.5VcAlm 00 Amber Blink CPU module #2 2.5-V power voltage alarm (lower…

Page 212

STATUS LED Indication Color State Suspected module Explanation Procedure CPU2 removed Green Blink CPU module #2 The CPU module has come off. Dismount…

Page 213

STATUS LED Indication Color State Suspected module Explanation Procedure = M = Memory U-Err 01 Green Blink CPU module #1 DIMM#1 2-bit error Memory…

Page 214 - POST Error Messages

POST Error Messages Powering on the server automatically starts the self-diagnostic program, POST (Power On Self-Test). When POST detects any error…

Page 215

On-screen error message Cause Action 0232 Extend RAM Failed at address line DIMM is faulty. Replace DIMM. Replace the CPU module board. 0233 Memory…

Page 216

On-screen error message Cause Action 0B29 Unsupported Processor detected on Processor 2 The processor (CPU) not supported by this server is installed…

Page 217

On-screen error message Cause Action 0B71 System temperature out of Range Ambient temperature is out of range. Fan is faulty. CPU/PCI module board is…

Page 218

On-screen error message Cause Action 0BD6 3rd SMBus device address not acknowledged 0BD7 3rd SMBus device Error detected 0BD8 3rd SMBus timeout - (3rd…

Page 219

On-screen error message Cause Action 8610 MAC Address update failed – CoreI/O#0 10/100Mbit Ethernet Controller FRB2 timeout occurred when setting MAC…

Page 220 - Error Notification by BEEP

Error Notification by BEEP An error message may not be displayed on the display unit even though the POST detected an error. In such a case, the beep…

Page 221 - Linux Error Messages

Linux Error Messages NEC Express5800/ft series displays messages on the console window when failures occur. Also, the same information is recorded as…

Page 222

Message Meaning Action FT[dev.no] info error initializing PCI slots Failed to initialize the PCI slot. There is no problem if any devices are not…

Page 223

Server Management Application Error Message If the server management tool such as NEC ESMPRO Agent or NEC ESMPRO Manager has been installed in the NEC…

Page 224 - SOLVING PROBLEMS

SOLVING PROBLEMS When the server fails to operate as expected, see the following to find out your problem and follow the given instruction before…

Page 225

Fail to power off the server: Is the POWER switch enabled? Restart the server and start the BIOS setup utility. <Menu to check: [Security] [Power…

Page 226

Some optional devices connected to the serial port require settings for I/O port address and operation mode. Refer to the manual that comes with the…

Page 227

The keyboard or mouse fails to operate: Is the cable properly connected? Make sure that the cable is connected to the correct connector on the rear of…

Page 228

If you still cannot access to the floppy disk using the methods above, perform the following operation and check if the floppy disk becomes…

Page 229

Is the CD-ROM device mounted? Perform the following procedure and check if you can access to the CD-ROM again. 1. Login to the system as a user with a…

Page 230 - ~ SETUP ~”.)

OS behavior is unstable: Have you changed kernel? Make sure that you have not applied patches for general kernel or you have not changed the kernel…

Page 231 - Event Log

LAN cards which are not used (LAN cables are not connected) appears to be in error status: The system judges that ports are out of order when LAN…

Page 232

used is 32. “APIC error” is recorded in the syslog by the operations such as inserting/removing disks: A message “APIC error” may be recorded to the…

Page 233

Problems with NEC EXPRESSBUILDER When the server is not booted from the NEC EXPRESSBUILDER CD-ROM, check the following: Did you set the NEC…

Page 234

Problems with Master Control Menu Failed to read online documentation Is HTML browser installed properly? Online documentation is an HTML-format file.…

Page 235 - Problems with NEC ESMPRO

Problems with NEC ESMPRO Agent See Chapter 5. NEC ESMPRO Manager See Chapter 5. See also online document in NEC EXPRESSBUILDER CD-ROM for…

Page 236 - COLLECTION OF TROUBLE LOGS

COLLECTION OF TROUBLE LOGS In the event of trouble, you can get information in the procedures described below: IMPORTANT: You can perform the…

Page 237 - Dump switches

Collection of the Memory Dump If a failure occurs, the memory data should be dumped to acquire the required information. IMPORTANT: Consult with your…

Page 238 - Backup of IPMI Information

Backup of IPMI Information Collect the IPMI information. NEC ESMPRO Agent must be installed to collect the information. 1. Login to the system as a…

Page 239 - Chapter 8

Chapter 8 System Upgrade This chapter describes procedures to add options and replace failed components. IMPORTANT: Optional devices described in this…

Page 240 - SAFETY PRECAUTIONS

SAFETY PRECAUTIONS Observe the following notes to install or remove optional devices safely and properly. WARNING Observe the following instructions…

Page 241 - ANTI-STATIC MEASURES

ANTI-STATIC MEASURES The server contains electronic components sensitive to static electricity. Avoid failures caused by static electricity when…

Page 242

PREPARING YOUR SYSTEM FOR UPGRADE Note the followings, when installing or replacing devices, to improve the performance of NEC Express5800/ft series.…

Page 243 - 3.5-INCH HARD DISK DRIVE

5-INCH HARD DISK DRIVE The 3.5-inch hard disk drive bay in front of the server contains six slots in which hard disks with the SCA2 interface are…

Page 244

Empty slots in the 3.5-inch hard disk drive bay contain dummy trays. The dummy trays are inserted to improve the cooling effect within the device.…

Page 245

Installing 3.5-inch Hard Disk Drive Follow the procedure below to install the hard disk. A hard disk may be installed in another slot in the same…

Page 246

Firmly hold the handle of the hard disk to install and insert the hard disk into the slot. TIPS: Insert the disk until the lever hook touches the…

Page 247

Removing 3.5-inch Hard Disk Drive Follow the procedure below to remove the hard disk. IMPORTANT: Make sure to read "Anti-static Measures" and…

Page 248

Replacing 3.5-inch Hard Disk Drive Follow the procedure below to remove the failed hard disk. If the hard disk fails, it should be replaced with new…

Page 249

RAID CONFIGURATION WHEN DISKS ARE ADDED When disks are added, ftdiskadm is used for RAID configuration. The following is an example of adding disks to…

Page 250

Check the disk status to confirm that the disk is added successfully.

Page 251 - CPU MODULE

CPU MODULE Concerning the CPU module, you can add or replace the following components, or CRU (customer-replaceable units): CPU (processor) DIMM…

Page 252 - Removing CPU Module

Removing CPU Module Follow the procedure below to remove the CPU module. 1. Stop the CPU module you want to remove. To this end, use the ft server…

Page 253 - Latch lever

Pull off the module halfway slowly. Pushing down the latch lever on the side to unlock it, pull the module off the rack. IMPORTANT: Carefully handle…

Page 254 - Installing CPU Module

Installing CPU Module Follow the procedure below to install the CPU module: IMPORTANT: Make sure to read "Anti-static Measures" and "Preparing Your…

Page 255

Close the release levers. IMPORTANT: Unless the release levers are located inside the rack frame, the module won’t be mounted correctly. 6. Screw the…

Page 256

DIMM The DIMM (dual inline memory module) is installed to the DIMM socket in the CPU module on the NEC Express5800/ft series. The CPU module board is…

Page 257

Note the followings to install or replace DIMM. The DIMMs with the same number are linked among the groups. When a DIMM is added to one group, another…

Page 258 - Installing DIMM

Installing DIMM Follow the procedure below to install the DIMM. Make sure to power off the server before starting installation except when replacing…

Page 259 - Removing DIMM

Removing DIMM Follow the procedure below to remove the DIMM. Make sure to power off the server before installation except when replacing DIMM. TIPS…

Page 260 - Replacing DIMM

Replacing DIMM Follow the procedure below to replace the failed DIMM. 1. Identify the failed DIMM using the Data Viewer of the NEC ESMPRO Manager. 2.…

Page 261 - PROCESSOR (CPU)

PROCESSOR (CPU) In addition to the standard CPU (Intel® Xeon™ Processor), you can add one CPU to make a multi-processor system. IMPORTANT: The CPU is…

Page 262 - Installation

Installation Follow the steps below to mount a CPU: 1. Shut down OS. Press the POWER switch to turn off the server. 2. Unplug the power cord. 3.…

Page 263 - Pin marks

Place the CPU carefully on the socket. TIPS: Pay attention to the orientation of the CPU. The CPU and socket have pin marks to prevent misinsertion.…

Page 264

Check to see if the heat sink is mounted parallel with the motherboard. IMPORTANT: If the heat sink is not parallel to the motherboard, dismount and…

Page 265 - Removing CPU

Removing CPU Follow the steps below to remove the CPU. Except when you replace the CPU with a new one, power off the server. IMPORTANT: Do not remove…

Page 266 - Replacing CPU

Replacing CPU Follow the steps below to replace a failed CPU: 1. Use Data Viewer of NEC ESMPRO Manager to check the failed CPU. 2. Remove the CPU…

Page 267 - PCI MODULE

PCI MODULE Three PCI boards can be installed to the PCI module. Up to two PCI boards can be added to each PCI module, therefore, the server can…

Page 268 - Precautions

Precautions If you remove a PCI module during operation, dual configuration of its internal hard disks will be cancelled. If you mount the module…

Page 269 - Removing PCI Module

Removing PCI Module Follow the procedure below to remove the PCI module. 1. Stop the PCI module you want to remove. To this end, use the ft server…

Page 270

Hold the release lever of the PCI module and pull it off. The PCI module is slightly pulled out toward you. IMPORTANT: Do not hold the other parts…

Page 271 - Installing PCI Module

Installing PCI Module Follow the procedure below to install the PCI module: IMPORTANT: Make sure to read "Anti-static Measures" and "Preparing Your…

Page 272 - 7. Close the release lever

Close the release lever. IMPORTANT: Unless the release levers are located inside the rack frame, the module won’t be mounted correctly. 8. Screw the…

Page 273 - PCI BOARD

PCI BOARD Up to three PCI boards can be installed to the PCI module (however, one video board is already installed in each module in standard…

Page 274 - Installing PCI Board

Installing PCI Board Follow the procedure below to install the board to be connected to the PCI board slot. TIPS: To install the PCI board, make sure…

Page 275 - Slots for inserting

Align the terminal segment of the board with the connection of the slot and insert the board slowly into the slot. TIPS: Check to see if the edge of…

Page 276

Align the PCI board with the guide rail groove and insert the board slowly. IMPORTANT: If the insertion is unsuccessful, remove the board once and…

Page 277 - Bends for fastening

In the case of a long board, slide the bracket to fasten the other edge of the board. Screw Bends for fastening boards 11. Install the top cover to…

Page 278

Use cable ties to fasten the extra length of cables. Cable ties (included with cabinet)

Page 279 - Removing PCI Board

Removing PCI Board Follow the procedure below to remove the PCI board. 1. Remove the PCI module. 2. Remove the PCI module’s top cover. 3. Remove the…

Page 280 - Replacing PCI Board

Replacing PCI Board Follow the procedure below to replace the failed PCI board. 1. Check the PCI board LED and identify the failed PCI board. When the…

Page 281 - Setup of Optional PCI Board

Setup of Optional PCI Board IMPORTANT: To enable the fault-tolerant feature of the optional device, the identical devices must be installed to the…

Page 282

Mount the N8804-001P1 100BASE-TX adapter to the slot with the same number in PCI module #1 and #2, and then start the OS. 2. Build a dual LAN…

Page 283 - N8104-84 1000BASE-SX Adapter

N8104-84 1000BASE-SX Adapter Consult your sales personnel for details when purchasing this hardware. IMPORTANT: Note the following about this product…

Page 284

PCI Board Status LED Indications LED indications Description Action Green Duplex is specified, however, the server works in simplex mode. Configure…

Page 285 - N8104-103 1000BASE-T Adapter

N8104-103 1000BASE-T Adapter Consult your sales personnel for details when purchasing this hardware. IMPORTANT: Note the following about this product…

Page 286

PCI Board Status LED Indications LED indications Description Action Green Duplex is specified, however, the server works in simplex mode. Configure…

Page 287

N8803-031F Fibre Channel Controller Slots to install the board PCI slot Group 1 Group 2 N code Name #1 #2 #3 Remarks N8803-031F Fibre Channel…

Page 288

Configure SCSI topology If you expanded the Fibre Channel Controller to the PCI slot, configuration of the topology is needed. Follow the procedure…

Page 289

Configure expanded LAN board Follow the procedure below to set the dual configuration of the 100BASE-TX, 1000BASE-T, 1000BASE-SX. Make the following…

Page 290 - Delete LAN board setting

Delete LAN board setting Follow the procedure below to delete the LAN board setting. IMPORTANT: You need to login to the system as a user with a root…

Page 291

Check the status of the LAN board Execute the following command to check the status of the LAN board: >vndctl status Example

Page 292 - Example

Check the setting information (e.g., IP addresses) Execute the following command to check the configuration information (e.g., IP addresses): >vndctl…

Page 293 - Appendix A

Appendix A Specifications NEC Express5800/320Lb NEC Express5800/320Lb-R Item N8800-057F N8800-058F CPU Type Intel Xeon™ Processor 1 Clock/second cache…

Page 294 - A-2 Appendix A

A-2 Appendix A (This page is intentionally left blank.)

Page 295 - Appendix B

Appendix B I/O Port Address The factory-set I/O port addresses for the server are assigned as follows: Address Chip in Use 00-1F 20-21 2E-2F 40-43 60…

Page 296 - B-2 Appendix B

B-2 Appendix B Address Chip in Use CA4-CA5 CA6-CA-7 CD6 CD7 CF8, CFC CF9 F50-F58h BAR4+00-0F IPMI (SMI interface) IPMI (SCI/SW1 interface) Power…

More documents for Software NEC Express5800/320Lb Linux

Questions about NEC Express5800/320Lb Linux

No questions about this manual yet. Ask the first one.

Ask a question

We answer from the manual and name the page. The question appears on the site after it is checked.

All questions and answers ›

Related products and manuals for Software NEC Express5800/320Lb Linux