Nec PlasmaSync 50MP2 User Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
46
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H
DATA02: BALANCE Gain EAH: -22
FFH: -01
00H: 0
01H: +01
16H: +22
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H
21. SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H
DATA00
CKS
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)
ACK
7FH 60H 80H 51H 01H
DATA00
CKS
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)
22. V. POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: V. POSITION Gain Flag 01H
DATA02: V. POSITION Gain C0H: -64
FFH: -01
00H: 0
01H: +01
40H: +64
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: V. POSITION Gain Flag 01H
23. H. POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00
DATA01
DATA02
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H. POSITION Gain Flag 02H
DATA02: H. POSITION Gain 80H: -128
FFH: -01
00H: 0
01H: +01
7FH: +127
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H. POSITION Gain Flag 02H
24. V-HEIGHT Gain Data
Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: V-HEIGHT Gain Flag 07H
DATA02: V-HEIGHT Gain 00H: 0
40H: +64
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: V-HEIGHT Gain Flag 07H
25. H-WIDTH Gain Data
Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H
DATA00 DATA01 DATA02
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H-WIDTH Gain Flag 08H
DATA02: H-WIDTH Gain 00H: 0
40H: +64
ACK
7FH 60H 80H 7FH 02H
DATA00 DATA01
CKS
DATA00: USER PICTURE Gain Flag 03H
DATA01: H-WIDTH Gain Flag 08H
Page view 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 67 68