Error! Style not defined. 4-55
Set MTBF Type
In this section, you can specify operations to be performed when failures occur on CPU or PCI
modules.
NEC Express5800/ft series manages the MTBF (mean time between failure) of hardware
components. If a fault occurs on a CPU or PCI module, the NEC Express5800/ft series calculates
the MTBF again. If the calculated value is lower than the pre-defined threshold, the NEC
Express5800/ft series disables the applicable module. Setting MTBF type for each module allows
you to restart or stop using the module without calculating the threshold when failures occur.
MTBF type description
“Use Threshold” (default)........If a failure occurs, the MTBF is calculated and the module is
stopped when the value becomes lower than the threshold.
“Never Restart”........................If a failure occurs, the module is stopped regardless of the MTBF.
“Always Restart” .....................If a failure occurs, the module is restarted regardless of the MTBF.
The default setting is “Use Threshold”.
IMPORTANT:
By clearing the MTBF, you can forcefully enable the component which has been
disabled because the MTBF value became lower than the threshold. Contact your
maintenance personnel if you want to enable the component forcefully.
If you set “Always Restart” for the MTBF type, the module may continue restarting
when a failure occurs. It is recommended to set “Use Threshold” for the MTBF type.
The module will be stopped automatically when it fails to restart repeatedly.
When the module is replaced, the MTBF type returns to the default setting “Use
Threshold”.
Procedure for setting MTBF type
1. From the [Start] menu, select [All Programs] – [NEC ESMPRO Agent] and then click [ft
server utility].
The [ft server utility] dialog box appears.
2. Select the module of which you want to change the MTBF type from the [CPU Module] or
[PCI module] on the [FT server] tree on the left pane. Then, select the MTBF type on the
[MTBF Type] on the right pane and click [Apply].
The MTBF type of the selected module will be changed.
IMPORTANT:
The MTBF type can be set for each module. To change the type of both PCI modules,
perform the process above for each module.
Page view 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 144 145

Comments to this Manuals

No comments

Epic Fitness A42t Sport Treadmill manuály

Uživatelské manuály a uživatelské příručky pro Běžecké pásy Epic Fitness A42t Sport Treadmill.
Poskytujeme 1 manuály pdf Epic Fitness A42t Sport Treadmill ke stažení zdarma podle typů dokumentů: Uživatelský manuál






Další produkty a příručky pro Běžecké pásy Epic Fitness

Modely Typ Dokumentu
705treadmill Uživatelský manuál   Epic Fitness 705treadmill User`s manual, 32 stránky
View 700 Treadmill Uživatelský manuál   Epic Fitness View 700 Treadmill User`s manual, 34 stránky
Tl 2710 Treadmill Uživatelský manuál   Epic Fitness Tl 2710 Treadmill User`s manual, 36 stránky
Tl 2300 Pro Treadmill Uživatelský manuál   Epic Fitness Tl 2300 Pro Treadmill User`s manual, 32 stránky
A35t Sport Treadmill Uživatelský manuál   Epic Fitness A35t Sport Treadmill User`s manual, 40 stránky