Nec MT830 User Manual Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
E-38
Cleaning Or Replacing The Filter
The air-filter sponge keeps the inside of the MultiSync MT830/
1030 LCD Projector free from dust or dirt and should be cleaned
after every 100 hours of operation (more often in dusty conditions).
If the filter is dirty or clogged, your projector may overheat.
NOTE: Clean your filter after every 100 hours of operation.
CAUTION
Turn off the main power and unplug the projector before
replacing the filter.
Only clean the outside of the filter cover with a vacuum
cleaner.
Do not attempt to operate the projector without a filter
cover.
Your LCD projector will not operate unless the filter cover
is installed correctly.
To clean the air-filter:
Vacuum the filter through the filter cover.
To replace the air-filter:
1. Remove the filter cover by pushing up on the catch of the
cover with a flat-head screwdriver until you feel it detach.
2. Reinstall the new filter cover.
NOTE: Do not detach the sponge from the filter cover. Do not
wash the filter cover with soap and water. Soap and
water will damage the filter membrane.
Before replacing the filter cover, remove dust and dirt
from the projector cabinet. Keep out dust and dirt
during filter replacement.
Remote Control Battery Installation
1. Press firmly and slide the battery cover off.
2. Remove both old batteries and install new ones (AA). En-
sure that you have the batteries' polarity (+/–) aligned cor-
rectly.
3. Slip the cover back over the batteries until it snaps into place.
Page view 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 47 48

Comments to this Manuals

No comments