7.37. POWER (read only) Control procedure
7.37.1. Current Power state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x2F)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x2F) : POWER parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Power state getting value
0 : Power off
1 : Power on