5.1.5 Information of module not supporting automatic update
5.1.5.1 Information of components
Information about each module not supporting automatic update is displayed at the below target.
/cmps/<Component Name>/map/expup/modules/unsupportedmod/<Module Name>
Properties and specific commands of this target are as follows.
Table 5-14 Properties of '/cmps/<Component Name>/map/expup/modules/unsupportedmod/<
Module Name>'
Property Access Description
Module read Displays a name of this module.
ExpUpStatus read An ExpressUpdate status of the moduls.
Statuses are as follows:
BLUE
RED
BLACK
Version read Displays current version of this module.
Severity read Displays a severity of the update. Severities are
as follows:
HIGH
MEDIUM
LOW
LatestApplyResult read Displays result of the most recent update.
If updates have never been executed, it shows
hyphen (-).
Table 5-15 Specific commands of '/cmps/<Component Name>/map/expup/modules/unsupporte
dmod/<Module Name>'
Command Description
set Changes ExpUpStatus of the module. "BLUE", "RED" and "BLACK" are able to be
specified.
Example
`show /cmps/<Component Name>/map/expup/modules/unsupportedmod/<Module Name>` command
enables you to view information about the module<Module Name> of the component<Component Name>.
-> show /cmps/Server01/map/expup/modules/unsupportedmod/"BMC Firmware "
ufip=/cmps/Server01/map/expup/modules/unsupportedmod/"BMC Firmware"
ufit="BMC Firmware"
Targets:
uppkgs
Properties:
Module=BMC Firmware
ExpUpStatus=BLUE
Version=3.0
Severity=HIGH
LatestApplyResult=-
Ver bs :
cd
exit
help
show
set
Page view 43