NEC PE6NMFY-000BZ90 Datasheet Page 128

  • Download
  • Add to my manuals
  • Print
  • Page
    / 160
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 127
SERVER & STORAGE SOLUTIONS
Enterprise Computing
Ultracare Services
NEC Standard
Warranty
Client Solutions
Ultracare Services


UPS SOLUTIONS FOR EXPRESS5800 SERVERS & NEC STORAGE SYSTEMS
APC’s Smart-UPS® Uninterruptible Power Supplies offer great reliability, availability, and management to help protect your NEC Express5800
servers and NEC Storage subsystems and appliances from power outages and disturbances.
In addition to providing seamless battery backup, the UPS solutions effortlessly integrate with NEC’s ESMPRO® server management platform
and with the Microsoft® Windows® 2003 and Red Hat® Linux® operating systems for smooth unattended shutdowns when needed.
HOW TO CHOOSE AN UNINTERRUPTIBLE POWER SUPPLY (UPS)
1 - Calculate the total VA (Volt x Ampere) power of the configuration to be connected to the UPS. (table 1)
2 - It is recommanded to allow some UPS power margin for future configuration expansion (ex: addition of future servers)
3 - Select the UPS corresponding to the calculated VA power and required autonomy (in minutes). (table 2)
ESTIMATED AUTONOMIE IN HOURS:MINUTES
SU 1500RM 2U SU RTD 5000RM XLI SURT 10000RMXLI
ABA-1520-00-00 ABA-5010-00-00 ENS-10KV-00-00
Watt VA hours:minuts:sec hours:minuts:sec hours:minuts:sec
50 70 5:21:00 6:56:00 7:34:00
100 140 3:05:00 4:35:00 5:39:00
200 280 1:31:00 2:40:00 4:10:00
300 420 0:55:00 1:51:00 3:10:00
400 560 0:37:00 1:23:00 2:33:00
500 700 0:26:00 1:06:00 2:07:00
600 840 0:19:00 0:55:00 1:48:00
700 980 0:14:00 0:47:00 1:34:00
800 1120 0:11:00 0:40:00 1:23:00
900 1260 0:09:00 0:35:00 1:14:00
1000 1400 - 0:31:00 1:06:00
1200 1680 - 0:25:00 0:55:00
1400 1960 - 0:21:00 0:47:00
1600 2240 - 0:17:00 0:41:00
1800 2520 - 0:15:00 0:36:00
2000 2800 - 0:13:00 0:32:00
2500 3500 - 0:09:00 0:24:00
3000 4200 - 0:07:00 0:19:00
3400 4760 - 0:05:00 0:17:00
TYPICAL POWER OF EXPRESS5800 SERVERS AND STORAGE
SUBSYSTEMS & APPLIANCES (VA) (TABLE 1)
INLET
Nb
INLET TYPE
POWER
INLET
SIDE
CABLE-
ARM
CABLE
LENGTH
Max WATT = Maximum power
consumption for full configuration
in watt
Max Curr. = Maximum current
required
Max BTU =
Maximum BTU dissi-
pated by equipment at maximum
power consumption
Inlet Nb NR =
Number of inlet plugs
for non redundant configuration
Inlet Nb R =
Number of inlet plugs
for non redundant configuration
Inlet type =
inlet plug type
Power supply side =
Looking from
the back of the device where the
PSU are placed Right Left Center
Cable-Arm / Cable Length =
minimum cable length W or W/O
cable arm to connect the device
SERVEUR Max WATT
Max Curr. Max BTU NR R IEC L/R W W/O
xI1310
0,00 0
110Ek
380 1,73 1297 1 C14
SI1720
550 2,50 1877 1 1 C14 R
SI1720 HS
650 2,95 2218 1 2 C14 R
SI1110-R1
350 1,59 1195 1 C14 R
SI1120-R1
350 1,59 1195 1 C14 R
120Rg-1 SATA
650 2,95 2218 1 C14 L
120Rg-1 SAS
650 2,95 2218 1 2 C14 L
120Rh-1 SAS/SATA Fixed PSU
650 2,95 2218 1 C14 L
120Rh-1 SAS/SATA HS PSU
750 3,41 2560 1 2 C14 L
120Ri-2 SAS
750 3,41 2560 1 2 C14 L
120Rj-2 SAS/SATA
750 3,41 2560 1 2 C14 L
120Eh-2
550 2,50 1877 1 1 C14 R
120Eh-2 HS
650 2,95 2218 1 2 C14 R
120Li
700 3,18 2389 1 2 C14 R 1350 NA
320Lb-R
1200 5,45 4096 2 C14 L NA
320Lc-R
1200 5,45 4096 2 C14 L NA
320Fb
1400 6,36 4778 2 C14 R NA
320Fc
1500 6,82 5120 2 C14 L NA
S1300 BAS
480 2,18 1638 0 2 C14 L/M NA 500
S1300 DEU
480 2,18 1638 0 2 C14 L/M NA 500
S1400 BAS
510 2,32 1741 0 2 C14 L/M NA 500
S1400 DEU
480 2,18 1638 0 2 C14 L/M NA 500
3U DEU ST1430
450 2,05 1536 1 2 C14 L/M 1350 NA
ST1430 U320
450 2,05 1536 0 2 C14 L/M 1350 NA
ST1220
400 1,82 1365 1 2 C14 R/L NA
Dx-10
500 2,27 1707 0 2 C14 R/M NA
S1500 BAS
510 2,32 1741 0 2 C14 L/M NA 500
S1500 DEU
480 2,18 1638 0 2 C14 L/M NA 500
140Hf
2100 9,55 7167 3 4 C14 R NA
140Re-4
1400 6,36 4778 2 4 C14 R NA
140Rf-4
1400 6,36 4778 2 C14 R/L NA
TW100 TS100
400 1,82 1365 1 C14 R NA
SYNERWAY SD1000
1300 5,91 4437 2 3 C14 R NA
SYNERWAY SD2000
1300 5,91 4437 0 3 C14 R NA
WA1310
400 1,82 1365 R
WI1510
550 2,50 1877
xA2510
670 3,05 2287 C14 R
xA2510 HS
0,00 0 C14 R
Page view 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 159 160