Page 6 NDA-30007 Revision 3.0
Application Configuration Conference Room Scheduler Installation Guide
Step 5 User-Defined Parameters (Both Components)
Make the following additional parameter entries through the UserDefined
command on the APM Configuration Entry screen.
Conf_Room_Sch
User-defined
Parameters
Parameter Entry Definition
Source Link Name OAI1X25 Identifies the port on the source side of
the communication link; entry should
correspond to a link name in the APM
system configuration file.
Destination Link Name PBX1X25 Identifies the port on the destination
side of the communication link; entry
should correspond to a link name in the
APM system configuration file.
Association Recovery 60 Designates the number of seconds
Conf_Room_Sch will wait before
trying to re-establish an association
with the NEAX that has been released.
User-defined Entry Definition
#1 4 Indicates the length of the identification
number assigned to each authorized
employee (maximum 9 digits.)
#2 /oai/app/data/crdata Specifies the path name of the
reservation database built and
maintained by Conf_Room_Sch as users
make, modify, and cancel conference
room reservations. (This path must be in
the same partition as /oai.)