Monitoring Ver. 3.2 or prior version of NEC ESMPRO Agent and DMI Agents
A function for monitoring Ver. 3.2 o r prior version of N EC ESMPRO Agent and D MI Agents has been remo ve
d from the N EC ESMPRO Mana ger Ver. 4.3 or l ater. As a resu lt, the Mana ger behaves as fo llows.
By performing auto-discovery, server icons are re gistered on th e Operation Window.
SNMP traps and DMI ev ents sent from monitor ed servers are dis played on the AlertViewer properly.
If the [Watch Server Status] properties are "On" for Ver. 3.0 o r prior version of NEC ESMPRO Agent, the
status color is displayed in gray (unknown). Set "Of f" for the [Watch Server S tatus] properties or delete t
he icon of th e Agent.
Status of DMI Agents is not monitored through DMI eve n if the "W atch Server S tatus" properties are "On".
The information of V er. 3.0 or prior versio n of NEC ESMPRO Agent and the DMI Agents is not viewed o
n the D ataViewer or th e GraphViewer, and not co llected by the Automatic Data Collection function.
Monitoring storages for NEC ESMPRO Agent Ver. 3.0 to V er. 3.1 is not supported.
Receiving DMI events from the machine belonging to multiple networks
Receiving DMI events from t he machine (with multiple IP addresses) belonging to multiple networks may not b
e available.
Using NEC ESMPRO Manager on a machine with a high load
When a machine on which the NEC ESMPRO Manager is installed is under high load:
If you use the machine with an extremely high load such as when 100% of the CPU has been used for a long time
period, the message "Communication with NVBase System Service became invalid" may appear.
Manager applications communicate with a service (NVBase System Service). The above message appears when
the communication is timed-out due to high load.
If this message appears, decrease the load on the machine and restart the application.
When a machine on which the NEC ESMPRO Agent is installed is under high load:
If a machine on which the NEC ESMPRO Agent is installed is operating with a high load, NEC ESMPRO Agent
does not respond to the query from the NEC ESMPRO Manager. Therefore, the following problems may occur:
- The icon for the machine is grayed out on the Operation Window.
- The following error messages are displayed when the DataViewer is started.
Could not collect information on the host.
Refer to Recovery Action for errors in DataViewer Help.
- The machine information becomes "Unknown" on the DataViewer