2. System BIOS Setup
Express5800/R120d-2E User’s Guide
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in Chapter 2 (1. System BIOS) in "Maintenance Guide".
Category Description Setting of parameter Remark
Basic Change date and time Configure date and time
Main → System Date
Main → System Time
Configurable on OS
On NumLock at power ON
→
→
Off the function to display the
logo during POST
Boot → Quite Boot → Disabled
By pressing the <Esc> key,
prevent the display of the logo.
Memory
Memory configure after add or
change DIMM
Advanced → Memory Configuration →
Memory Retest → Yes
After rebooting, Memory Retest
changes No automatically.
Use memory RAS feature Change to RAS mode
Advanced → Memory Configuration →
Memory RAS Mode
You can select Mirroring, Lock
Step, or Sparing.
Optional
board
Disable Option ROM Scan of
installed option board
Advanced → PCI Configuration → PCI
Device Controller and Option ROM
Settings → PCIXX Slot Option ROM →
Enabled
XX is PCI slot number of the
option board
Boot
Change the boot order of
devices
Change the boot priority
Boot → Boot Option Priorities
When you use
EXPRESSBUILDER, set
CD/DVD to the highest priority.
Use remote power on feature
(via modem)
Advanced → Advanced Chipset
Configuration → Wake On Ring →
Enabled
Use remote power on feature
(via RTC alarm)
Advanced → Advanced Chipset
Configuration → Wake On RTC Alarm
→ Enabled
Use console redirection feature
Advanced → Serial Port Configuration
→ Console Redirection Setting →
Change respective setting.
Security
Set a password to restrict
operation of SETUP Utility
Set a password
Security → Administrator Password
Security → User Password
If password is set, a
message to enter password
is displayed at next time
SETUP is launched.
Set a password to restrict Boot
Security → Password On Boot →
Enabled
You can select this parameter
after you set password.
UPS
Powerlink
When the server is supplied
with power from UPS, always
turn on the power.
Server → Power Control
Configuration → AC-LINK → Power
On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Server → Power Control
Configuration → AC-LINK → Last
State
Keep the power OFF even
when UPS supplies power.
Server → Power Control
Configuration → AC-LINK → Stay off
Comments to this Manuals