NEC Express5800/R110d-1E Installation Guide Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
44
In case of key-in failure on the Remote Console
During DOS boot or access to the removable media immediately after the managed server's po wer switch
is turned ON, data ca nnot be keyed in from th e remote console or th e keyed data display may be delay
ed.
Remote Console is reali zed by using the Serial Over LAN (SOL) function of the IPMI confo rmity and the
Serial Redirection function of BIOS.
Data cannot be keyed in from the Remote Console when the firmware(BIOS and so o n) or the software r
equires the k ey code that VT100 terminal emulator (the hyper-terminal and so o n) can't control.
Refer to the document of ea ch firmware or software for the d etails.
RAID EzAssist Configuration Utility
To operate RAID EzAssist for a SOL-i ncompatible managed server from the CUI re mote console via LAN, set
the item " Console Redirection" to "Disable" on the BIOS Setup Ut ility screen, re boot the s ystem, and th en boo
t the RAID Ez Assist Configuration Utility.
Power management
If you set the value o n the managed server which does not support power management, you cannot put
back the v alue to "u nsetting". Set "zero" t o each value, it is acce pted as "uns etting".
The electric p ower value might not n ecessarily reach even the v alue of Po wer Cap value.
The electric power control lowers the power consumption of the s ystem by lowering the fr equency of CPU
/ Memory.
When CPU / Memory Throttling value reaches 100%, the electric power value doesn't fall an y more.
CPU blade auto registration
When "Check Connection" of "CPU b lade auto registration" was failed. You can execute "Check Connection" o
n "Server Pr operties" - "Connection Setting".
If a specified IP address is set from a CPU blade to another CPU blade during "CPU blade auto registration"
process (ex. when you replace CPU blade and execut e "CPU b lade auto registration"), NEC ESMPRO Mana
ger may not be able to connect the CPU blade beca use old in formation remains in the ARP table on the ma
nager server. Wait for a fe w minutes and try the " Check Connection".
Coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC ESMPRO
Agent Extension on the same server
If the managed server is installed Advanced Remote M anagement Card or E XPRESSSCOPE Engine series (th
e BMC uses exclusive LAN port (m anagement LAN port)), NEC ESM PRO Manager can m anage the server its
elf installed. It th e managed server is in stalled BMC that u ses the standard LAN port, N EC ESMPRO Manage
r cannot manage the ser ver itself installed. It is possib le only to i nstall NEC ESM PRO Manager and Di anaSco
pe Agent or NEC ESMPRO Agent Extension on the same server. But the communication with BMC on the se
rver is p revented by local loopback function of OS and the BMC cannot receive any p ackets from the NEC E
SMPRO Manager.