[Example 1] When Logical Drive 1 on RAID Controller 2 is degraded.
- Jun 27 18:49:04 localhost raidsrv[27370]: <RU0402> [CTRL:2(ID=1) LD:1(ID=0)] Logical Drive is
Degraded.
Item Description
raidsrv Indicates the process name of Universal RAID Utility
<RU0402> Indicates event ID. The four numeric characters after “RU” is event ID.
CTRL:2(ID=1) Indicates the RAID Controller number. The example “CTRL:2(ID=1)” indicates the RAID
Controller of which the RAID Controller number is 2 and ID is 1.
LD:1(ID=0) Indicates the Logical Drive number. The example “LD:1(ID=0)” indicates the Logical
Drive of which the Logical Drive number is 1 and ID is 0.
[Example 2] When the status of the Physical Device e49s1 connected to the RAID Controller 2 changes to
Ready.
- Jun 27 18:49:04 localhost raidsrv[27370]: <RU0302> [CTRL:2(ID=1) PD:e49s1(ID=72) ATA
ST380815AS A ] Physical Device is Ready.
item
説明
raidsrv Indicates the process name of Universal RAID Utility
<RU0302> Indicates event ID. The four numeric characters after “RU” is event ID.
CTRL:2(ID=1) Indicates the RAID Controller number. The example “CTRL:2(ID=1)” indicates the RAID
Controller of which the RAID Controller number is 2 and ID is 1.
PD:e49s1(ID=72) Indicates the Physical Device number. The example “PD: e49s1 (ID=72)” indicates the
Physical Device of which the Physical Device number is e49s1 and ID is 72.
ATA ST380815AS
A
Indicates the product name of the Physical Device.
Buzzer in RAID Controller
If a RAID Controller is equipped with a Buzzer, the RAID Controller sounds the Buzzer for some types of failures
occurred.
The Buzzer sounds until the stopping it by RAID Viewer or raidcmd. This section describes how to stop the
Buzzer.
RAID Viewer
Step 1
Start the RAID Viewer. Check the component in which a failure occurs on the Tree View.
Step 2 Click the RAID Controller containing the component in which the
failure occurs. The click [Silence Buzzer] on the [Control] menu.
You can click menu item [Silence Buzzer] whether a Buzzer sounds or not. Nothing is done if
no Buzzer sounds.