NEC Express5800/R110f-1E User Manual Page 116

  • Download
  • Add to my manuals
  • Print
  • Page
    / 135
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 115
ESMPRO User Group is the name group for the management of NEC ESMPRO Manager
(specified it when installed NEC ESMPRO Manager). If you forget the name of group, see the
following registry key.
CPU architecture (x86) : HKEY_LOCAL_MACHINE\SOFTWARE\NEC\NVBASE
CPU architecture (x64) : HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node \NEC\NVBASE
Value : LocalGroup
Monitoring Faults of Physical Devices
The Universal RAID Utility can take the following measures to monitor failures of Physical Devices detected by RAID
Controllers.
RAID Viewer
raidcmd
RAID Log Buzzer OS Log Alert
 
Depending on type of
RAID Controller


If a Physical Device used for a Logical Drive is failed, the status of the Physical Device changes to [Failed].
In addition, the status of the Logical Drive using the Physical Device changes to [Degraded] or [Offline] depending on
the redundancy. The status of the Physical Device and Logical Drive remains unchanged until the problem is solved.
If the Physical Device (SSD) used as CacheCade fails, the status of the Physical Device (SSD)
changes to Fail and the capacity of the SSD Cache Drive that includes the Physical Device
(SSD) decreases.
SSD Cache Drive operates as Read Cache of HDD. Therefore, if the status of any one of the
Physical Devices (SSD) is “Online”, the status of the SSD Cache Drive is “Online”.
The RAID
Viewer indicates the status of Physical Devices and Logical Drives with their icons on the Tree View and their
properties. In addition, the RAID Viewer shows the status from the viewpoint of the RAID System and from the viewpoint
of the server on the Tree View.
The raidcmd indicates the status of Physical Devices and Logical Drives on their properties.
The display of the RAID Viewer depending on the change of Physical
Device status is described below.
[
S
y
mbols
]
Lo
g
ical drive
Ph
y
sical device
Physical device (Hot Spare)
116
Page view 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 134 135

Comments to this Manuals

No comments