raidcmd
Step 1 Execute raidcmd without command to check the component where a failure occurs.
Step 2 Execute "sbuzzer" command with the
following parameter.
-c : Number of the RAID Controller for which Buzzer is
stopped
115
Ex. Stop the Buzzer of the RAID Controller (RAID Controller number:1)
raidcmd sbuzzer -c=1
Sending Alert to ESMPRO Manager
Among RAID System events logged in the OS Log, the Universal RAID Utility sends important events which may
affect the operations and managements of the server to the NEC ESMPRO Manager as alerts. To send alerts,
the event monitoring function provided by the NEC ESMPRO Agent can be used. If the NEC ESMPRO Agent is
installed in the server in which the Universal RAID Utility is installed and alert transmission is set, RAID System
events detected by the Universal RAID Utility will be automatically subject to alert transmission to the NEC
ESMPRO Manager.
For alerts sent to the NEC ESMPRO Manager, see " Appendix C : Logs/Events ".
For alert transmission provided by the NEC ESMPRO Agent, see the relevant documentation
of the NEC ESMPRO Agent.
Using report coordination of NEC ESMPRO/AlertManager
To use alerts on report coordination of the NEC ESMPRO/AlertManager, add the following registry to the
computer in which the NEC ESMPRO Manager is installed.
If the registry has existed already, you do not need to correct the registry additionally.
Registry key
CPU architecture (x86) :
HKEY_LOCAL_MACHINE\SOFTWARE\NEC\NVBASE\AlertViewer\AlertType\URAIDUTL
CPU architecture (x64) :
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\NEC\NVBASE\AlertViewer\AlertType\URAIDUTL
Values
Name Type Data
WavDefault REG_SZ Default.wav
AniDefault REG_SZ Default.bmp
Image REG_SZ Default.bmp
SmallImage REG_SZ Default.bmp
Permission
In case of the operation system where ESMPRO Manager is installed is Windows XP (exclude Home Edition),
Windows 2000, or Windows Server 2003, add the following permissions.
Name Type
Administrators Full Control
Everyone Read
SYSTEM Full Control
ESMPRO User Group Full Control