8-4 Troubleshooting
STATUS lamp
indication
Description Procedure
On (green) The server is operating normally.
Flashing
(green)
The server is operating with the
memory, CPU, or power supply
unit in degraded state.
A single-bit memory error has
often occurred.
Check the AC POWER lamp indication
on the rear panel of the server.
Identify the device in degraded state
by using the BIOS setup utility
"SETUP," and replace it as soon as
possible.
The power is off.
POST is in progress. Wait for a while. The STATUS lamp
turns green when POST is completed.
A CPU error occurred.
A CPU temperature alarm was
detected. (Thermal-Trip)
A timeout occurred when the time
set for the watchdog timer arrived.
A CPU bus error occurred.
Turn the power off and then turn it on.
If the POST screen displays an error
message, take notes of the message,
and contact your sales representative.
Off*
A memory dump request is made. Wait until the memory dump is
completed.
A temperature alarm was detected. Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
A voltage alarm was detected.
On (amber)*
All the power supply units failed.
Contact your sales representative.
Either of the following was detected
in the redundant power
configuration:
AC power not supplied to one of
the two power supply units
Failure of one of the two power
supply units
Connect the power cord to supply
power. If the power supply unit is
faulty, contact your sales
representative.
A fan alarm was detected.
Check if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
A temperature warning was
detected.
Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
Flashing
(amber)*
A power supply alarm was detected. Contact your sales representative.
* Indicates only when the optional remote management card is installed in your system.
Page view 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 313 314

Comments to this Manuals