1. POST Error Message
Express5800/R120d-1M, R120d-2M Maintenance Guide
101
Chapter 3 Appendix
(1) Error messages
Error Message
Cause
Solution
8000 System variable is
corrupted.
Illegal setup information of
BIOS was detected.
Start BIOS Setup Utility (SETUP), and then
execute Load Setup Defaults and specify the
necessary settings.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8001 Real time clock error
Real time clock error was
detected.
Start SETUP, and then specify the correct date
and time.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8002 Check date and time settings
Incorrect date and time set on
real time clock was detected.
8003 System battery is dead -
Replace and run SETUP
The battery for storing system
settings is dead.
Contact your sales representative to request a
battery replacement. (After the replacement, start
SETUP, and then specify the correct settings.)
8005 Previous boot incomplete -
Default configuration used
The previous POST processing
did not finish.
Use SETUP to specify the correct settings.
8006 System configuration data
cleared by Jumper.
The setup utility settings were
cleared using the jumper.
Follow the steps described in Chapter 1 (7.
Resetting and Clearing the Server).
Start SETUP, and then setup each item again.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
This error message also appears when lithium
battery is removed.
8007 SETUP Menu Password cleared
by Jumper.
The setup utility password was
cleared using the jumper.
8020 BIOS update error.
BIOS update failed. Try BIOS update again.
If the same error is detected repeatedly, contact
your sales representative.
8021 Recovery jumper is set, but
recovery images is not
found.
Recovery jumper is set. Contact your sales representative.
8800 DXE_NB_ERROR
An error was detected during
initialization of chipset.
8801 DXE_NO_CON_IN
An error was detected during
initialization of console.
8802 DXE_NO_CON_OUT
8803 PEI_DXE_CORE_NOT_FOUND
A flash ROM is corrupt.
8804 PEI_DXEIPL_NOT_FOUND
8805 DXE_ARCH_PROTOCOL_NOT_AVA
ILABLE
8806 PEI_RESET_NOT_AVAILABLE
The system was not reset
correctly.
8807 DXE_RESET_NOT_AVAILABLE
Follow the steps described in Chapter 1 (7.
Resetting and Clearing the Server).
Start SETUP, and then setup each item again.
If the same error is detected repeatedly in spite of
re-setting, contact your sales representative.
8808 DXE_FLASH_UPDATE_FAILED
The Flash ROM was not written
to correctly.
Contact your sales representative.
8830 PEI_RECOVERY_NO_CAPSULE
The Flash ROM was not
recovered correctly.
8831 PEI_RECOVERY_PPI_NOT_FOUN
D
8832 PEI_RECOVERY_FAILED
9000 Unsupported CPU detected
An unsupported CPU was
detected.
9001 Unsupported CPU detected on
CPU #1
9002 Unsupported CPU detected on
CPU #2
9021 Unsupported CPU Speed
detected on CPU #1
A CPU of which clock speed is
unsupported was detected.
9022 Unsupported CPU Speed
detected on CPU #2