CHAPTER 3 NDA-24296
Page 298
Revision 1.0
PA-8LCBR
Line Circuit
5. Switch Settings
Switches on this circuit card have the following meanings.
Note 1:
When Caller ID is in service, set SW16-1 to OFF (Separate mode).
Note 2:
Valid when SW16-1 is set to ON (Common mode).
SWITCH
NAME
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
SW00
(MB)
UP Circuit card make busy
DOWN Circuit card make busy cancel
SW10
1ON×
Fixed
2OFF×
3OFF×
4OFF×
SW11
1OFF×
Fixed
2OFF×
SW12
1OFF×
Fixed
2OFF×
SW13
1OFF×
Fixed
2OFF×
SW14
1
ON Momentary Open
OFF Polarity Reverse
2
ON
Message Waiting Lamp flashes
(1-sec. ON, 1-sec. OFF)
OFF
Message Waiting Lamp lights or flashes
(Selected and Controlled by software)
SW15
1OFF× Fixed
2
ON Stutter Dial Tone is available
OFF Stutter Dial Tone is not available
SW16
1
Note 1
ON Ringer Timer mode: Common mode
OFF Ringer Timer mode: Separate mode
2
Note 2
ON Pre-ringing is not available
OFF
Pre-ringing is available