CHAPTER 3 NDA-24296
Page 514
Revision 1.0
PA-8ILCE-A
ISDN Terminal Line Circuit
OFF
Short Passive Bus mode: This mode is also a point-to-multipoint mode, in which a maximum of eight terminals can be
connected anywhere on the bus. Note that the bus length is limited to 200 m in this case.
Extended Passive Bus mode: This mode is a point-to-multipoint mode, in which up to eight terminals can be connected.
Note that the terminals must be connected within 50 m from the end of the bus cables as shown below.
max 600 m
Modular Rossete
ILC
TE
max 400m
Modular Rossete
TE TE
max 50m
max 200 m
Modular Rossete
ILC
TE
TE
Modular Rossete
Modular Rossete
Terminals can be connected any location on the bus.
Note:
Set the SW04 to determine the 4-wire bus mode referring to the following.
ILC
(in the case of 0.5φ [mm])
(in the case of 0 .5φ [mm])
(in the case of 0.5φ [mm])
(with terminating
resistor (100))
(with terminating
resistor (100))
(with terminating
resistor (100))
ON
Point-to-Point mode: In this mode one Terminal Equipment (TE) can be connected at the end of up to a maximum of 600
m of cable as shown below.
Page view 539