NDA-24296 CHAPTER 3
Page 551
Revision 1.0
PA-4AMPC
AMP Pool Trunk
5. Switch Settings
Standard settings of various switches on this circuit card are shown in the table below.
SWITCH
SWITCH
SETTING
STANDARD
MEANING
NAME NO.
SETTING
(MB)
UP Circuit card make busy
DOWN
×
Circuit card make busy cancel
0
ON The corresponding circuit is in make busy state.
OFF
×
Make busy of the corresponding circuit is canceled.
SW01
1
ON The corresponding circuit is in make busy state.
OFF
×
Make busy of the corresponding circuit is canceled.
2
ON The corresponding circuit is in make busy state.
OFF
×
Make busy of the corresponding circuit is canceled.
3
ON The corresponding circuit is in make busy state.
OFF
×
Make busy of the corresponding circuit is canceled.
1OFF
×
Fixed
2OFF
×
Fixed
3OFF
×
Fixed
Both ECa (Public Line) side and ECb (Tie Line)
ON side operate. (When this switch has been set to ON,
set SW10, SW11, and SW12 to right side.)
4
SW02
Only ECa (Public Line) side operates.
OFF
×
(When this switch has been set to OFF, set SW10, SW11,
and SW12 to left side.)
5OFF
×
Fixed
6OFF
×
Fixed
7OFF
×
Fixed
8OFF
×
Fixed
SW00