NDA-24296 CHAPTER 3
Page 557
Revision 1.0
PA-8TLTR
Tie Line Trunk
5. Switch Settings
Standard settings of switches on this circuit card are shown in the table below.
SWITCH
SWITCH
NO.
SETTING
STANDARD
SETTING
MEANING
MB
(SW00)
UP Circuit card make busy
DOWN
×
Circuit card make busy cancel
MB0 - 7
(SW01)
0
ON Make busy of the No. 0 circuit
OFF
×
Make busy cancel of the No. 0 circuit
1
ON Make busy of the No. 1 circuit
OFF
×
Make busy cancel of the No. 1 circuit
2
ON Make busy of the No. 2 circuit
OFF
×
Make busy cancel of the No. 2 circuit
3
ON Make busy of the No. 3 circuit
OFF
×
Make busy cancel of the No. 3 circuit
4
ON Make busy of the No. 4 circuit
OFF
×
Make busy cancel of the No. 4 circuit
5
ON Make busy of the No. 5 circuit
OFF
×
Make busy cancel of the No. 5 circuit
6
ON Make busy of the No. 6 circuit
OFF
×
Make busy cancel of the No. 6 circuit
7
ON Make busy of the No. 7 circuit
OFF
×
Make busy cancel of the No. 7 circuit