Displayed Error Message Description Recommended Action
C106 BMC set in progress
monitoring timeout.
The BMC check was interrupted.
C107
BMC command access
failed.
BMC command access failed.
C108 Could not redirect
the console - BMC Busy -
Console redirection was not
possible (BMC busy).
C109 Could not redirect
the console - BMC Error -
Console redirection was not
possible (BMC error).
C10A Could not redirect
the console - BMC
Parameter
Error -
Console redirection was not
possible (BMC parameter error).
C10B BMC Platform Information
Area corrupted.
C10C BMC update firmware
corrupted.
BMC device (chip) error
Turn off the power, and
then restart the server.
If this does not resolve
the problem, contact
your service
representative.
C10D Internal Use Area of
BMC FRU corrupted.
Failure of the SROM for storing
chassis information
This is not a fatal error,
but turn off the power,
and then restart the
server. If this does not
resolve the problem,
contact your service
representative.
C10E BMC SDR Repository
empty.
BMC device (chip) error
Turn off the power, and
then restart the server.
If this does not resolve
the problem, contact
your service
representative.
C10F IPMB signal lines do
not respond.
SMC (Satellite Management
Controller) failure
This is not a fatal error,
but turn off the power,
and then restart the
server. If this does not
resolve the problem,
contact your service
representative.
C110 BMC FRU device failure.
Failure of the SROM for storing
chassis information
This is not a fatal error,
but turn off the power,
and then restart the
server. If this does not
resolve the problem,
contact your service
representative.