NEC Express5800/R110f-1E User Manual Page 107

  • Download
  • Add to my manuals
  • Print
  • Page
    / 135
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 106
raidcmd
107
Step 1
Execute "stspd" command with -st option
and the following parameters.
-c : Number of the RAID Controller containing the Physical
Device with its status set to Online forcibly
-p : Number of the Physical Device with its status set to
Online forcibly
-st : Specify "online"
Ex. Make the Physical Device (RAID Controller
Number: 1 and Physical Device Number: e252s4)
Online forcibly.
raidcmd stspd -c=1 -p=e252s4 -st=online
Step 2 Displays the Warning message and the
confirmation message. Type "yes" to reply to the
confirmation message. Then Status of the Physical
Device is changed to Online. Type "No" to abort the
change status of the Physical Device.
Step 3 If "stspd" command succeeds, the Status
of the Physical Device is set to Online.
Use the “property” command to see the property of the Physical Device.
-tg: Specify pd to see the property of the Physical Device.
-c: The number of the RAID Controller in which the Physical Device exists.
-p: The number of the Physical Device.
1
2
3
Seri
al Number : 3LC05ZZG
Capacity : 33GB
Status : Online
S.M.A.R.T. : Normal
Power Status : On
>
> raidcmd stspd -c=1 -p=e252s4 -st=online
Make the Physical Device e252s4 online.
[Warning]
The consistency of Logical Drive will be lost.
Do you continue ? [yes(y) or no(n)] : yes
> raidcmd property -tg=pd -c=1 -p=e252s4
RAID Controller #1 Physical Device e252s4
Enclosure : 252
Enclosure Position : Internal
Slot : 4
ID : 21
Device Type : HDD
Interface : SAS
Vendor/Model : SEAGATE ST936701SS
Firmware Version : 0003
Ex. Check the property of the Physical Device (RAID Controller number: 1 and Physical Device number: e252s4).
raidcmd property -tg=pd -c=1 -p=e252s4
To Failed Forcibly
To set the Status of a Physical Device to Failed forcibly, use Make Offline. The procedure of executing Make
Offline is described below.
The redundancy of Logical Drive will be lost if you forcibly change the status of the Physical
Device used for the Logical Drive.
RAID Viewer
Step 1
Start the RAID Viewer. Click a Physical Device with Status bei
Online on the Tree View. Then click [Make Offline] on the [Control] menu.
ng
Step 2 Displays the Warning message and the confirmation
message. Click [Yes], then Status of the Physical Device is
changed to Failed.
Then click [No], without changing the status of the Physical
Device.
Step 3 After the Make Offline succeeds, Status of the Physical Device is changed to Failed.
Page view 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 134 135