Standard and Advanced Modes
The RAID Viewer and raidcmd can operate in two RAID System Management Modes, which are Standard Mode and
Advanced Modes.
The Standard Mode provides the RAID Viewer and raidcmd with standard management functions for RAID Systems.
The Advanced Mode provides the RAID Viewer and raidcmd with advanced management and maintenance functions for
RAID Systems.
Using the two RAID System Management Modes appropriately depending on users and jobs allows the usability of the
RAID Viewer to be improved and malfunctions to be avoided.
The table below lists the functions of the RAID Viewer and raidcmd available in each mode.
Function RAID Viewer
function
raidcmd
command
Standard
mode
Advanced
mode
See the version About... in [Help] menu run raidcmd without
command
 
view Tree View run raidcmd without
command
 
Start Log Viewer Log Viewer NA
 
Update display information Rescan rescan
 
Change RAID System Management Mode Standard Mode
Advanced Mode
runmode
 
See property Property property
 
See status of operation Operation View oplist
 
Hot Spare (make) Make Hot Spare hotspare
 
Hot Spare (remove) Remove Hot Spare hotspare
 
Easy Configuration Easy Configuration econfig
 
Create Logical Drive (simple) Create Logical Drive
(Simple)
mklds
 
Create Logical Drive (custom) Create Logical Drive
(Custom)
mkldc

Delete Logical Drive Delete Logical Drive delld

Create SSD Cache Drive Create SSD Cache Drive mkscd

Delete SSD Cache Drive Delete SSD Cache Drive delscd

Set option parameters of RAID Controller Property of RAID Controller optctrl

Set option parameters of Logical Drive Property of Logical Drive optld

Consistency Check (start) Start Consistency Check cc
 
Consistency Check (stop) [Stop] on Operation View cc
 
Consistency Check (start)
for schedule running
NA ccs
 
Initialize (start) Start Initialize init

Initialize (stop) [Stop] on Operation View init

Rebuild (start) Start Rebuild rebuild

Rebuild (stop) [Stop] on Operation View rebuild

Location of Physical Device Locate slotlamp
 
Change Status of Physical Device (Online) Make Online stspd

Change Status of Physical Device (Failed) Make Offline stspd

Refresh Battery Refresh Battery refresh

Refresh Battery for schedule running NA refreshs
 
Silence Buzzer Silence Buzzer sbuzzer
 
