Page view 65
Step 4 If the Dedicated Hot Spare is created
successfully, you can find that the value of [Status] is
set to [Hot Spare] and item [Hot Spare Information]
appears newly with value [Dedicated (Disk Array #X)].
raidcmd
Step 1 Execute "hotspare" command with -mr
option and the following parameters.
-c : Number of the RAID Controller containing the Physical
Device with which a Hot Spare is made
-p : Number of the Physical Device with which a Dedicated
Hot Spare is made(The capacity of the Physical Device
should be equal to any Physical Device used by the target
Disk Array)
-mr : Specify "make" to make Dedicated Hot Spare
-a : Number of the target Disk Array using the Dedicated
Hot Spare
66
Ex. Create a Dedicated Hot Spare for the Disk Array
(Disk Array Number:2) using a Physical Device with
RAID Controller number: 1 and Physical Device
number: e252s5).
raidcmd hotspare -c=1 -p=e252s5 -mr=make -a=2
Step 2 If you see the Dedicated Hot Spare is created successfully, you find that the value of [Status] is changed to
[Hot Spare] and new item [Hot Spare Information] appears with value [Dedicated].
Use the “property” command to refer to the property of Physical Device.
-tg : Specify pd to refer to the property of Physical Device.
-c : Number of the RAID Controller to which the Physical Device is connected
-p : Number of the Physical Device
Ex. Refer to the property of the Physical Device with RAID Controller number:1 and Physical Device number: e252s5.
raidcmd property -tg=pd -c=1 -p=e252s5
Removing Hot Spare
The procedure of removing a Hot Spare is described below.
RAID Viewer
Step 1 Start the RAID Viewer. Click a Physical Device with [Status] being [Hot Spare] on the Tree View.
2
1
>
Seri
al Number : 6XM009S2
Capacity : 135GB
Status : Hot Spare
Hot Spare Information : Dedicated (Disk Array #2)
S.M.A.R.T. : Normal
Power Status : On
Firm
ware Version : NQY1
Vendor/Model : SEAGATE ST9146853SS
Interface : SAS
Device Type : HDD
ID : 23
Slot : 5
> raidcmd hotspare -c=1 -p=e252s5 -mr=make -a=2
Make Dedicated Hot Spare.
Do you continue ? [yes(y) or no(n)] : yes
> raidcmd property -tg=pd -c=1 -p=e252s5
RAID Controller #1 Physical Device e252s5
Enclosure : 252
Enclosure Position : Internal
Step 2 Select [Hot Spare] on the [Control] menu
and click [Remove Hot Spare].
Step 3 If the Hot Spare is created successfully,
you can find that the value of [Status] of the Physical
Device property is set to [Ready] and item [Hot Spare
Information] disappears.
Page view 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 134 135

Comments to this Manuals

No comments